APAR status
Closed as documentation error.
Error description
Point of problem: This problem is that "Instantiate From Document" is not performed by the error when "PowerCopy" has a feature of "As Result With Link". . Setup of the option: 1) Select "Tools" > "Options" by menu bar. "Option" dialog box is displayed. 2) Select "Part Infrastructure" on the tree. 3) Select "General" tab. 4) Activate "Keep link with selected object". 5) Activate "Restrict external selection with link to published elements". 6) Click "OK". . Process: 0) Start CATIA. Check of "PowerCopy" - 1) Open the file : "G00266_PC.CATPart". Workbench : "Generative Shape Design". (Please confirm that "PowerCopy.1" is "Geometrical Set.2" including "Point.2" which is "As Result With Link".). This is key point. (Please confirm that the parent of "Point.2" is "Point.1" which is the input element.) 2) Close this file. . Perform the instance- 3) Open the file : "G00266.CATPart". Workbench : "Generative Shape Design". 4) Select "Insert" > "Instantiate From Document" by menu bar. "File Selection" dialog box is displayed. 5) Select "G00266_PC.CATPart". 6) Click "Open". "Insert Object" dialog box is displayed. 7) Select "AAA". 8) Click "OK". "Error" window is displayed. This is problem. "Error" message. Instantiation cannot be performed Paste is forbidden : Impossible to create an external reference from unpublished element. This is the problem. . Result "Instantiate From Document" is not performed by the error when "PowerCopy" has a feature of "As Result With Link". This is problem. The published element displayed by the error message is not needed because it is link inside "CATPart". . .
Local fix
Problem summary
Point of problem: This problem is that "Instantiate From Document" is not performed by the error when "PowerCopy" has a feature of "As Result With Link". . Setup of the option: 1) Select "Tools" > "Options" by menu bar. "Option" dialog box is displayed. 2) Select "Part Infrastructure" on the tree. 3) Select "General" tab. 4) Activate "Keep link with selected object". 5) Activate "Restrict external selection with link to published elements". 6) Click "OK". . Process: 0) Start CATIA. Check of "PowerCopy" - 1) Open the file : "G00266_PC.CATPart". Workbench : "Generative Shape Design". (Please confirm that "PowerCopy.1" is "Geometrical Set.2" including "Point.2" which is "As Result With Link".). This is key point. (Please confirm that the parent of "Point.2" is "Point.1" which is the input element.) 2) Close this file. . Perform the instance- 3) Open the file : "G00266.CATPart". Workbench : "Generative Shape Design". 4) Select "Insert" > "Instantiate From Document" by menu bar. "File Selection" dialog box is displayed. 5) Select "G00266_PC.CATPart". 6) Click "Open". "Insert Object" dialog box is displayed. 7) Select "AAA". 8) Click "OK". "Error" window is displayed. This is problem. "Error" message. Instantiation cannot be performed Paste is forbidden : Impossible to create an external reference from unpublished element. This is the problem. . Result "Instantiate From Document" is not performed by the error when "PowerCopy" has a feature of "As Result With Link". This is problem. The published element displayed by the error message is not needed because it is link inside "CATPart". .
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN THE DOCUMENTATION DELIVERED WITH VERSION V5R20 Additional Closure Information: Documentation Reference: Infrastructure User's Guide Chapter: Basic Tasks or (if Other): Topic: Manipulating Objects - Using the Paste Special... Command . Documentation after correction : The following warning has been added: "If you copy an internal import As specified, you will generate an import (internal or external according to the target document) of the original import's reference." . Additional Information: When the object of "As Result With Link" exists in "Selected components" of "PowerCopy", the object of "As Result With Link" is pasted to other part. When the object of "As Result With Link" is pasted to other part, link reference of the object becomes an original object. This behavior is the specification in the case of paste on other part. .
Temporary fix
Comments
APAR Information
APAR number
HD88293
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-08-28
Closed date
2009-09-15
Last modified date
2009-09-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
15 September 2009