IBM Support

HD87848: FTA/ WHEN OPENING R18 FILES IN R19 SP3, CRITICAL FDT DATA IS LO ST.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • Scenario:
    When opening R18 files in R19 SP3, critical data is lost
    without any evidence of error.
    EX- Certain required painted surfaces are omitted
    (not visible) in R19 SP3.
    It is not reliable and will result in scrapped parts.
    Flag note designations in R19 are not highlighting
    the same as prior versions which renders r19 unusable.
    

Local fix

Problem summary

  • SCENARIO:
    .
    1. Start CATIA.
    2. Open the CATPart.
    .
    RESULTS:
    When opening R18 files in R19 SP3, critical data is lost
    without any evidence of error.
    Ex- Certain required painted surfaces are omitted (not
    visible) in R19 SP3.
    Flag note designations in R19 are not highlighting the same
    as prior versions.
    .
    EXPECTED RESULTS:
    The Critical FDT data should not be lost when opening R18 files
    in R19SP03.
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON CATIA  VERSION V5R19.
    THIS PROBLEM IS NOT REPRODUCIBLE ON CATIA VERSION V5R20 GA
    level and CATIA  VERSION V5R19 SP6.
    Additional Closure Information:
    INCIDENT DIAGNOSIS:
    FTA/ When opening R18 files in R19 SP3, critical FDT data is
    lost.
    .
    EXPLANATION:
    The behavior is corrected and is same as it was in R18 level.
    All the painted surfaces are shown correctly.
    .
    

APAR Information

  • APAR number

    HD87848

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-11

  • Closed date

    2009-08-24

  • Last modified date

    2009-10-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN SP51906

       UP09/10/27 I 1000