Problem: Unable to save corrupt file to local disk SCENARIO: 1. Open the provided CATPart from local disk into CATIA V5. 2. Run CATDUA. 3. Save back to local disk. RESULT: The save operation fails with the following error message: "Save Operation failed: Problem while writing file" . EXPECTED RESULT: The CATPart should be saved to the local disk. .
Local fix
Problem summary
Problem: Unable to save corrupt file to local disk SCENARIO: 1. Open the provided CATPart from local disk into CATIA V5. 2. Run CATDUA. 3. Save back to local disk. RESULT: The save operation fails with the following error message: "Save Operation failed: Problem while writing file" . EXPECTED RESULT: The CATPart should be saved to the local disk.
Problem conclusion
Temporary fix
Comments
INCIDENT DIAGNOSIS: Unable to save corrupt file to local disk . DEVELOPMENT JUSTIFICATION: 1. The CATPart is quite big in term of numbers of objects (even small objects). 2. In GenericNaming container, there are differents objects : one is called the scope: there is one scope for each feature (a simple point is also a feature). In the scope we have nodes (each node correspond to an element with a name ) . In the streamed file, the number of nodes of a scope is stored on an integer as there could be a large amount of nodes in one scope. Before R20, it was stored on a short integer (max was 65535). In the provided CATPart, there is at least one scope which have about 85000 nodes, so it cannot be stored correctly in R19 level. The way to store this number in R19 cannot be changed even in a SP. So the problem cannot be corrected in R19 in any SP. The correction will be available from R20GA level.
APAR Information
APAR number
HD87499
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-07-28
Closed date
2009-10-22
Last modified date
2009-10-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R519 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
22 October 2009