HD86788: PS: CATIA CRASH WHEN OPENING IN NEW WINDOW AFTER MODIFYING A PA RT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SCENARIO:
    1. Start CATIA V5 with the provided CAT settings.
    2. Right-click on Product1 / Components / New Part
    3. Open the Part in a New Window (right-click on
    Part1 / Part1.1 object /Open in New Window)
    4. Change WB: Start / Mechanical Design / Part
    Design
    5. Select xy plane / Sketch / Rectangle
    6. Exit Sketcher
    7. Pad / OK
    8. Exit Window (of Part1) / Close Message
    Appears / Click No
    (Don?t save changes)
    9. Re-Open the Part in a New Window (right-click
    on Part1 / Part1.1 object / Open in New Window)
    10. Double-Click on the Part1 in the new Window...
    .
    OBSERVATION:
    CATIA crashes with Runtime exception "Click OK to
    terminate" or directly without any message.
    .
    

Local fix

Problem summary

  • SCENARIO:
    1. Start CATIA V5 with the provided CAT settings.
    2. Right-click on Product1 / Components / New Part
    3. Open the Part in a New Window (right-click on
    Part1 / Part1.1 object /Open in New Window)
    4. Change WB: Start / Mechanical Design / Part
    Design
    5. Select xy plane / Sketch / Rectangle
    6. Exit Sketcher
    7. Pad / OK
    8. Exit Window (of Part1) / Close Message
    Appears / Click No
    (Don?t save changes)
    9. Re-Open the Part in a New Window (right-click
    on Part1 / Part1.1 object / Open in New Window)
    10. Double-Click on the Part1 in the new Window...
    .
    OBSERVATION:
    CATIA crashes with Runtime exception "Click OK to
    terminate" or directly without any message.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON   VERSION V5R20 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP6.
    Additional Closure Information:
    Incident Diagnosis:
    CATIA crash after modifying a CATPart used in two open
    Products.
    .
    Correction Explanation:
    The pointed document history was not cleared.
    Now the history is not taken into consideration.
    There is no crash of CATIA.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD86788

  • Reported component name

    CATIA V5 AIX

  • Reported component ID

    569101000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-07-22

  • Closed date

    2009-08-06

  • Last modified date

    2009-10-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 AIX

  • Fixed component ID

    569101000

Applicable component levels

  • R519 PSN SP51906

       UP09/10/27 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
27 October 2009