APAR status
Closed as Permanent restriction.
Error description
Expanded status of the specification tree is not saved. . SCENARIO1: 1) Start CATIA. 2) Open the provided CATPart. 3) Notice the Geometrical Set is not expanded in the Specification tree. 4) Hide and then unhide the XY plane. 5) Expand the Geometrical Set in the the Specification tree. 6) Save the CATPart. 7) Open the saved CATPart again. . OBSERVATION: Notice that Geometrical Set is in expanded state in the Specification tree. . SCENARIO2: 1) Start CATIA. 2) Open the provided CATPart. 3) Notice the Geometrical Set is not expanded in the Specification tree. 4) Expand the Geometrical Set in the the Specification tree. 5) Hide and then unhide the XY plane. 6) Save the CATPart. 7) Open the saved CATPart again. . OBSERVATION: Geometrical Set is not in expanded state in the Specification tree. . EXPECTED RESULT: When opening the CATPart, the Geometrical Set should be in the same state in which it was while saving the CATPart. .
Local fix
Problem summary
Expanded status of the specification tree is not saved. . SCENARIO1: 1) Start CATIA. 2) Open the provided CATPart. 3) Notice the Geometrical Set is not expanded in the Specification tree. 4) Hide and then unhide the XY plane. 5) Expand the Geometrical Set in the the Specification tree. 6) Save the CATPart. 7) Open the saved CATPart again. . OBSERVATION: Notice that Geometrical Set is in expanded state in the Specification tree. . SCENARIO2: 1) Start CATIA. 2) Open the provided CATPart. 3) Notice the Geometrical Set is not expanded in the Specification tree. 4) Expand the Geometrical Set in the the Specification tree. 5) Hide and then unhide the XY plane. 6) Save the CATPart. 7) Open the saved CATPart again. . OBSERVATION: Geometrical Set is not in expanded state in the Specification tree. . EXPECTED RESULT: When opening the CATPart, the Geometrical Set should be in the same state in which it was while saving the CATPart.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA. Additional Closure Information: INCIDENT DIAGNOSIS: Expanded status of the specification tree is not saved. . RESTRICTION EXPLANATION: Expanding or Collapsing the specification tree should not force the part to be saved when closing the part. On the other hand, Hide or Show is considered as a modification in part and will force the part to be saved when closing the part. . Hence when user performs first the expand and collapse operation on specification tree, then the part is not modified. Thus the state of specification tree is not remembered. After this step if user performs hide and show operation then part is modified and only this operation is saved. . When user performs the hide and show operation first then the part is modified and a save is required. After this step if the specification tree is expanded or collapsed then its state is being considered while saving the part as the part is already modified. This is because expand or collapse modifies a model attribute only if the part is already modified. Hence the state of specification tree is kept while saving the part. . A correction on the expand or collapse algorithm to always save the status of the specification tree will corrupt the part leading to a permanent restriction of this behaviour. Also an unnecessary save will be required everytime the specification tree is collapsed or expanded. . BY-PASS: To save the expand or collapse state of specification tree, perform some modification command on part (for example hide and show operation)
Temporary fix
Comments
APAR Information
APAR number
HD86391
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-07-08
Closed date
2009-09-11
Last modified date
2009-09-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: