Error description
ABSTRACT: DMUOPT: 3D Cut (DMU Optimzer) is removing part instead of cutting SCENARIO: 01. Launch CATIA V5R19SP03 02. Open CATProduct 03. Change to the DMU Optimizer Workbench 04. Select root product & Click the 3D-Cut icon 05. Select Tab "Definition". Select Cutting Type "Cuts the outer parts of the product". Select On the Border type "Cuts the triangles". 06. Select Tab "Position". Click "Edit Position and Dimensions" Enter following values: x=-100; Y=2; Z=0; Width=60; Height=100; Thickness=200 07. Close the position dialog and click "Preview". RESULT: The cylinder is not cut but completely removed. EXPECTED RESULT: The cylinder should be cut, not removed. .
Local fix
Problem summary
ABSTRACT: DMUOPT: 3D Cut (DMU Optimzer) is removing part instead of cutting SCENARIO: 01. Launch CATIA V5R19SP03 02. Open CATProduct 03. Change to the DMU Optimizer Workbench 04. Select root product & Click the 3D-Cut icon 05. Select Tab "Definition". Select Cutting Type "Cuts the outer parts of the product". Select On the Border type "Cuts the triangles". 06. Select Tab "Position". Click "Edit Position and Dimensions" Enter following values: x=-100; Y=2; Z=0; Width=60; Height=100; Thickness=200 07. Close the position dialog and click "Preview". RESULT: The cylinder is not cut but completely removed. EXPECTED RESULT: The cylinder should be cut, not removed.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP4. Additional Closure Information: Incident Diagnosis: 3D Cut (DMU Optimzer) is removing part instead of cutting. Technical Explanation of the correction: Now we are throwing an error message and informing the user in case of non-watertight volumetric input to the 3DCut command. We have published an article in knowledge base to give more details regarding this message: QA00000007042 The input of the 3D Cut command is constituted of a tessellated data-set (triangulated data, or triangular mesh), as well as a 3D box defining the volume to cut. The 3D Cut command attempts to cut the selected tessellated data-set using the input 3D box. When it is run, the command identifies all those input volumes which are not closed. Once such a volume is identified, a warning message is now displayed regarding it, and the 3D Cut operation is completed as previously. The aim of this warning message is to explain why the 3DCut command sometimes appears to provide incorrect results even though the CATIA model appears to be OK. Note: If the warning pop-up is closed & the preview window is closed now Preview button is again clicked then the warning message won't be displayed. ByPass: Re-tessellating the input may help in running the command without any error message related to "open-volume". Check the knowledge article QA00000006132 for details.
Temporary fix
Comments
APAR Information
APAR number
HD86145
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-06-30
Closed date
2010-08-12
Last modified date
2010-08-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 August 2010