APAR status
Closed as program error.
Error description
ABSTRACT: "Synchronize all external references when updating" is not changed to activation when CATIA is restarted. SCENARIO: 1) Open the attached CATProduct. 2) Workbench is "DMU Kinematics". 3) Select Tools>Options by menu bar. "Option" dialog box is displayed. 4) Select "Part Infrastructure" on the tree. 5) Select "General" tab. (Please confirm that "Synchronize all external references when updating" is activated) 6) Click Cancel. 7) Expand "Applications" on the tree until "Mechanism1, DOF=0" is displayed. 8) Double-click "Mechanism1, DOF=0"."Kinematics Simulation" dialog box is displayed. "Simulation Information" window is displayed. 9)"Simulation Information" message Reads as follows Contextual parts have been detected. Therefore, 'Update all external references' Part Infrastructure option has been deactivated. The option will be activated again as soon as you close the current document. 10) Click "OK" on the window. 11) Click "Close" on the dialog box. 12) Select "Tools" > "Options" by menu bar. "Option" dialog box is displayed. "Synchronize all external references when updating" was changed to deactivation. (This is the right behavior.) 13) Click "Cancel". 14) Close CATIA without save.(This is key point). 15) Restart CATIA. 16) Select "Tools" > "Options" by menu bar."Synchronize all external references when updating" is not changed to activation.This is the problem. RESULT: "Synchronize all external references when updating" is not changed to activation after restart of CATIA. EXPECTED RESULT: "Synchronize all external references when updating" should be changed to activation even if CATIA is restarted. .
Local fix
Problem summary
ABSTRACT: "Synchronize all external references when updating" is not changed to activation when CATIA is restarted. SCENARIO: 1) Open the attached CATProduct. 2) Workbench is "DMU Kinematics". 3) Select Tools>Options by menu bar. "Option" dialog box is displayed. 4) Select "Part Infrastructure" on the tree. 5) Select "General" tab. (Please confirm that "Synchronize all external references when updating" is activated) 6) Click Cancel. 7) Expand "Applications" on the tree until "Mechanism1, DOF=0" is displayed. 8) Double-click "Mechanism1, DOF=0"."Kinematics Simulation" dialog box is displayed. "Simulation Information" window is displayed. 9)"Simulation Information" message Reads as follows Contextual parts have been detected. Therefore, 'Update all external references' Part Infrastructure option has been deactivated. The option will be activated again as soon as you close the current document. 10) Click "OK" on the window. 11) Click "Close" on the dialog box. 12) Select "Tools" > "Options" by menu bar. "Option" dialog box is displayed. "Synchronize all external references when updating" was changed to deactivation. (This is the right behavior.) 13) Click "Cancel". 14) Close CATIA without save.(This is key point). 15) Restart CATIA. 16) Select "Tools" > "Options" by menu bar."Synchronize all external references when updating" is not changed to activation.This is the problem. RESULT: "Synchronize all external references when updating" is not changed to activation after restart of CATIA. EXPECTED RESULT: "Synchronize all external references when updating" should be changed to activation even if CATIA is restarted. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON VERSION V5R20 GA level. Additional Closure Information: Incident Diagnosis: Temporary deactivation does not return in the case of restart Closure description: In V5R20GA Level, the CATSetting is Restored when session is closed, so the problem is fixed. In V5R19SP6 level,there has been a Change in the Simulation Information warning message displayed in case of Contextual Part. The updated warning message is as follows "Contextual Parts have been detected. Therefore, 'Synchronize a ll external references' Part infrastructure options has been de activated. The option will be activated again as soon as you cl ose the current document. Please be sure to close the document window first before closing the CATIA session" .
Temporary fix
Comments
APAR Information
APAR number
HD85662
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-06-12
Closed date
2009-08-04
Last modified date
2009-10-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN SP51906
UP09/10/27 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
27 October 2009