HD84523: FTA / FAKE DIMENSION IS CHANGED WHEN UPDATE PART.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • FTA / Fake dimension is changed when update part.
    .
    Scenario.
    .
    1.Start Catia R19 SP3
    2.Open the CATPart
    3.The Part and Annotation Set are requiring an
    update
    4.Upon update, the value for Linear Size.1 is
    changing from 1.3937 to .3937
    .
    Expected result
    .
    After update the value should not be changed to
    0.3937.
    .
    

Local fix

Problem summary

  • FTA / Fake dimension is changed when update part.
    FTA / Fake dimension is changed when update part.
    .
    Scenario.
    .
    1.Start Catia R19 SP3
    2.Open the CATPart
    3.The Part and Annotation Set are requiring an
    update
    4.Upon update, the value for Linear Size.1 is
    changing from 1.3937 to .3937
    .
    Expected result
    .
    After update the value should not be changed to
    0.3937.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    Incident Diagnosis
    Semantic dimension created in user data uses a
    fake dimension value.
    Fake mode is ignored for semantic dimension.
    During update of the CATPart, the semantic
    dimension does not keep the fake value.
    .
    Restriction Explanation.
    A fake value should not be applied to a semantic
    dimension. Purpose semantic dimension is not to
    provide fake values.
    .
    User has to create a non semantic dimension in
    order to define a fake value.
    .
    Please refer documentation on following path for
    information:
    3D Functional Tolerancing & Annotation
    Reference Information
    Non-semantic and Semantic Usage
    Note that semantic Toleranced dimensions cannot
    be faked.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD84523

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-04-29

  • Closed date

    2009-05-12

  • Last modified date

    2009-05-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 May 2009