Error description
SCENARIO1: 1) Start CATIA R19SP3. 2) Open the CATPart. 3) Select the Sketch.1 and copy it. 4) Create a new Part. 5) Paste the copied sketch in this new part by right clicking on PartBody and selecting paste. 6) Create a pad of length 1000 mm using this sketch. 7) Copy and Paste the Sketch.1 of Part1 in the same PartBody. Sketch.2 is created. 8) Right click on Sketch.2 and select Change Sketch support. 9) Select Sketch Positioning : Positioned. 10) Select Reference: Face of the pad as seen in the avi file 11) Select Origin : Barycenter. 12) Reference: Face of the pad as seen in the avi file. . OBSERVATION: The sketch is incorrectly positioned (on a different plane). . SCENARIO2: 13) Right click on Sketch.2 again and select Change Sketch support. 14) Do not change any value and select OK. . OBSERVATION: The sketch is now correctly positioned. . SCENARIO3: 15) Try to create a pad using the sketch obtained after step 14. . OBSERVATION: The pad cannot be created correctly. .
Local fix
Problem summary
SCENARIO1: 1) Start CATIA R19SP3. 2) Open the HEA100_mdtv.CATPart. 3) Select the Sketch.1 and copy it. 4) Create a new Part. 5) Paste the copied sketch in this new part by right clicking on PartBody and selecting paste. 6) Create a pad of length 1000 mm using this sketch. 7) Copy and Paste the Sketch.1 of Part1 in the same PartBody. Sketch.2 is created. 8) Right click on Sketch.2 and select Change Sketch support. 9) Select Sketch Positioning : Positioned. 10) Select Reference: Face of the pad as seen in the avi file 11) Select Origin : Barycenter. 12) Reference: Face of the pad as seen in the avi file. . OBSERVATION: The sketch is incorrectly positioned (on a different plane). . SCENARIO2: 13) Right click on Sketch.2 again and select Change Sketch support. 14) Do not change any value and select OK. . OBSERVATION: The sketch is now corectly positioned. . SCENARIO3: 15) Try to create a pad using the sketch obtained after step 14. . OBSERVATION: The pad cannot be created correctly. .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Additional Closure Information: INCIDENT DIAGNOSIS: Incorrect position of a pasted sketch after performing change sketch support operation on it. . DEVELOPMENT REQUEST JUSTIFICATION: The provided data has corrupted internal links which causes the incorrect behaviour seen with sketch positioning operation. The issue is not reproduced with a similar sketch created from scratch. In addition the creation scenario of data is unknown. R&D team will analyse this new model configuration having corrupted links after creation history of such data is made available. . ANSWER AND BYPASS: To correct the corrupted internal links, the sketch positioning operation should be performed once again after the sketch is p ositioned in incorrect place. In Sketch Positioning dialog, sel ect Type as Sliding and again as Positioned and then select the Origin type as Barycenter. .
Temporary fix
Comments
APAR Information
APAR number
HD84097
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-13
Closed date
2009-08-21
Last modified date
2009-08-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
21 August 2009