Error description
STCAI / View temporary copy - Check OUT icon not updated . 1. Create Part1.CATPart with no geometry in it. Save it and Check-In it to SmarTeam. 2. File Open For Edit of Part1.CATPart. Create some geometry in it. Save it and Check-In it to SmarTeam. Two revisions now exists: "" revision and "a.0" revision 3. In SmarTeam, select the latest revision "a.0" and perform a File Operation / Open For " / View temporary copy. Part1.CATPart "a.0" is opened to CATIA V5 but cannot be checked-out. CATIA, CGR Files and FileCatalog info are created in Temp directory of user 4. In SmarTeam, select the first revision "" and perform a File Operation / Open For " / Open as read-only. Part1.CATPart "" is opened to CATIA V5. Two windows are now opened in CATIA V5. 5. In CATIA V5, select the first revision "" and perform SmarTeam / Assembly Management / Replace with Selected Revision. Select the revision "a.0" 6. Check out the part . Problem: Check OUT icon not updated directly. . Expected Result: Check OUT icon should be updated directly .
Local fix
Problem summary
STCAI / View temporary copy - Check OUT icon not updated STCAI / View temporary copy - Check OUT icon not updated . 1. Create Part1.CATPart with no geometry in it. Save it and Check-In it to SmarTeam. 2. File Open For Edit of Part1.CATPart. Create some geometry in it. Save it and Check-In it to SmarTeam. Two revisions now exists: "" revision and "a.0" revision 3. In SmarTeam, select the latest revision "a.0" and perform a File Operation / Open For " / View temporary copy. Part1.CATPart "a.0" is opened to CATIA V5 but cannot be checked-out. CATIA, CGR Files and FileCatalog info are created in Temp directory of user 4. In SmarTeam, select the first revision "" and perform a File Operation / Open For " / Open as read-only. Part1.CATPart "" is opened to CATIA V5. Two windows are now opened in CATIA V5. 5. In CATIA V5, select the first revision "" and perform SmarTeam / Assembly Management / Replace with Selected Revision. Select the revision "a.0" 6. Check out the part . Problem: Check OUT icon not updated directly. . Expected Result: Check OUT icon should be updated directly .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 20 GA LEVEL. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19SP05 . Incident Diagnosis In the scenario, Latest version document is opened in CATIA session. Then the same document (old verison) is opened from different path. Both of them are opened in CATIA session in two different editor windows. There was no check. . Correction Explanation . Check is done to detect presense of the Document in CATIA Session. If already Document exist in session, a warning message is fired while opening another verison document. . --------------------------- Warning --------------------------- The document with the same identification is already loaded from following location: C:\Documents and Settings\user\LocalSettings\Temp\BF8F9C9D-4489- 43DD-84B8-8C86E67DA760\CATPRT-0349.CATPart. It is not possible to re-open the same document from another location --------------------------- OK --------------------------- . .
Temporary fix
Comments
APAR Information
APAR number
HD83458
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-03-20
Closed date
2009-06-09
Last modified date
2009-07-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SMARTEAM NT>XP
Fixed component ID
569199970
Applicable component levels
R519 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
31 July 2009