  • Problem:
    Different PostProcessor was selected.
    .
    Scenario:
    1. Build the attached workspace.
    2. Launch the CATIA.
    3. Go to Tools > Option > Machining > Output >
    Post Processor and Controller Emulator Folder.
    4. Check the "Other PP" option and click OK.
    5. Switch to "Surface Machining" workbench.
    6. Double click on "Part Operation.1"
    7. Click on "Machine" icon.
    8. Go to "Numerical Control" tab.
    9. Select the Post Processor as "My PP 1" and click
    OK.
    10. Now launch the "Generate NC Code
    Interactively" command.
    11. Go to "NC Code" tab and confirm the Post-
    processor file name.
    .
    Actual Result:
    Selected Post Processor is "My PP 2"
    .
    Expected Result:
    Selected Post Processor should be "My PP 1" as set
    in step 9.
    .
    

Local fix

Problem summary

  • Different PostProcessor was selected
    Problem:
    Different PostProcessor was selected.
    .
    Scenario:
    1. Build the attached workspace.
    2. Launch the CATIA.
    3. Go to Tools > Option > Machining > Output >
    Post Processor and Controller Emulator Folder.
    4. Check the "Other PP" option and click OK.
    5. Switch to "Surface Machining" workbench.
    6. Double click on "Part Operation.1"
    7. Click on "Machine" icon.
    8. Go to "Numerical Control" tab.
    9. Select the Post Processor as "My PP 1" and click
    OK.
    10. Now launch the "Generate NC Code
    Interactively" command.
    11. Go to "NC Code" tab and confirm the Post-
    processor file name.
    .
    Actual Result:
    Selected Post Processor is "My PP 2"
    .
    Expected Result:
    Selected Post Processor should be "My PP 1" as set
    in step 9.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 20 GA LEVEL.
    .
    Incident Diagnosis:
    Different PostProcessor was selected
    .
    Correction Explanation:
    The user entered Post-processor names were
    stored in a sorted manner for picking up the entry
    in the NC Output Panel which led to a mismatch.
    Now the PP entries for the external Post-Processor
    Provider will appear in the same order as they are
    in the implementation of the method GetListOfPPs
    for the interface CATIMfgExternalPPManagement.
    .
    Answer and By-Pass
    In the implementation of the interface
    CATIMfgExternalPPManagement enter the name of
    the PPs in a sorted manner.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD83195

  • Reported component name

    CAA V5 NT>XP

  • Reported component ID

    569151100

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2009-03-13

  • Closed date

    2009-05-27

  • Last modified date

    2009-05-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CAA V5 NT>XP

  • Fixed component ID

    569151100

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
22 August 2024