IBM Support

HD82850: REPORTER (STRBOM) RETURNS INCORRECT LENGTH ON ST_FRAME PROFILE WITH ENDCUT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Reporter (STRBOM) returns incorrect length on
    ST_Frame profile with endcut
    Scenario: -
    1. Create ST_Frame/Place/unspec/Beam 2X2X.25
    length 20.002"
    2. This beam should intersect another Beam
    2X2X.25
    at a 90 degree angle
    3. Run STRMTL(STRBOM) reporter on Beam
    created in
    step 1. Reporter should return value Member
    length=20.002
    4. Cope Beam 1 into Beam 2 using
    ST_frame/Perform/Cutback/Manual/Notching
    5. Run STRMTL(STRBOM) reporter on Beam
    created in
    step 1. Reporter should return value Member
    length=20.002
    6. Create splitting plane to represent snipe angle 7.
    Create snipe using ST_Frame/Perform/Split
    8. Run STRMTL(STRBOM) reporter on Beam
    created in
    step1
    RESULT : Reporter now returns value Member
    length 19.502
    EXPECTED RESULT: Reporter should return the
    value as 20.002
    .
    

Local fix

Problem summary

  • Reporter (STRBOM) returns incorrect length on ST_Frame profile
    with endcut
    Reporter (STRBOM) returns incorrect length on
    ST_Frame profile with endcut
    Scenario: -
    1. Create ST_Frame/Place/unspec/Beam 2X2X.25
    length 20.002"
    2. This beam should intersect another Beam
    2X2X.25
    at a 90 degree angle
    3. Run STRMTL(STRBOM) reporter on Beam
    created in
    step 1. Reporter should return value Member
    length=20.002
    4. Cope Beam 1 into Beam 2 using
    ST_frame/Perform/Cutback/Manual/Notching
    5. Run STRMTL(STRBOM) reporter on Beam
    created in
    step 1. Reporter should return value Member
    length=20.002
    6. Create splitting plane to represent snipe angle 7.
    Create snipe using ST_Frame/Perform/Split
    8. Run STRMTL(STRBOM) reporter on Beam
    created in
    step1
    RESULT : Reporter now returns value Member
    length 19.502
    EXPECTED RESULT: Reporter should return the
    value as 20.002
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA V425SP15
    Incident Diagnosis
    Reporter (STRBOM) returns incorrect length on
    ST_Frame profile with endcut
    Correction Explanation
    The STRBOM reporter for STF profile with endcut
    was not taking account correctly of the endcut.
    Problem is fixed now
    Answer and By-Pass
    None
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD82850

  • Reported component name

    CATIA V4 AIX

  • Reported component ID

    562610000

  • Reported release

    425

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-03-04

  • Closed date

    2009-06-04

  • Last modified date

    2009-09-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V4 AIX

  • Fixed component ID

    562610000

Applicable component levels

  • R425 PSN UH95315

       UP09/07/07 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSLJ45","label":"CATIA-CADAM"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"425","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
30 September 2009