IBM Support

HD81085: DMUFIT: REPLAY HAULTS IN THE MIDDLE IN THE SIMULATION PLAYER.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABSTRACT:
    DMUFIT: REPLAY HAULTS IN THE MIDDLE IN THE
    SIMULATION PLAYER.
    .
    SCENARIO:
    1. Launch V5R19SP2 &
    open "Play_Stop.CATProduct" and change to DMU
    Fitting workbench.
    2. Expand Applications in the tree, expand Tracks,
    and double click on Shot (shot).
    3. From Player toolbar, pull down Parameter Value,
    select Shot and click on OK in the Track dialog.
    4. From menu bar, select [Tools / Simulation /
    Player].
    5. Expand Applications- Sequences in the tree and
    select Sequence.
    6. Select Parameters icon in Player toolbar and
    select 2s in Sampling Step field.
    7. From Player toolbar, select Play Forward (Right)
    icon to replay Sequence.
    .
    RESULT:
    Replay halts in the middle at Simulation Player.
    .
    EXPECTED RESULT:
    Replay should not halt in the middle at Simulation
    Player even when Parameter Value is set by Step.
    .
    

Local fix

Problem summary

  • DMUFIT: REPLAY HAULTS IN THE MIDDLE IN THE SIMULATION PLAYER.
    ABSTRACT:
    DMUFIT: REPLAY HAULTS IN THE MIDDLE IN THE
    SIMULATION PLAYER.
    .
    SCENARIO:
    1. Launch V5R19SP2 &
    open "Play_Stop.CATProduct" and change to DMU
    Fitting workbench.
    2. Expand Applications in the tree, expand Tracks,
    and double click on Shot (shot).
    3. From Player toolbar, pull down Parameter Value,
    select Shot and click on OK in the Track dialog.
    4. From menu bar, select  Tools / Simulation /
    Player .
    5. Expand Applications- Sequences in the tree and
    select Sequence.
    6. Select Parameters icon in Player toolbar and
    select 2s in Sampling Step field.
    7. From Player toolbar, select Play Forward (Right)
    icon to replay Sequence.
    .
    RESULT:
    Replay halts in the middle at Simulation Player.
    .
    EXPECTED RESULT:
    Replay should not halt in the middle at Simulation
    Player even when Parameter Value is set by Step.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 20 GA LEVEL.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R19SP05.
    Incident Diagnosis
    DMUFIT: REPLAY HAULTS IN THE MIDDLE IN THE
    SIMULATION PLAYER.
    Correction Explanation
    Tracks store their mode as agent's class variable, it
    allows them to have consistent mode across the
    sessions. Now at the start of the play, The mode is
    taken from simulation player itself and reset to
    original value at the time of exit.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD81085

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-01-05

  • Closed date

    2009-04-21

  • Last modified date

    2009-07-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN SP51905

       UP09/07/31 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
31 July 2009