IBM Support

HD80937: ASD:COMPASS ROTATION INCREMENTS NOT BEING HONORED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ASD:Compass rotation increments not being
    honored
    .
    SCENARIO:
    1) Open any assembly that contains a sub
    assembly
    2) Set the compass rotation increments to 90
    degrees
    3) Place (or set snap) and rotate a part within the
    assembly. Note that the part honors the 90 degree
    setting.
    4) Open one of the sub assemblies from the higher
    level assembly in a New Window.
    5) Set the compass rotation increments to 30
    degrees
    6) Place (or set snap) and rotate a part within the
    sub assembly. Note that the part honors the 30
    degree setting.
    7) Return to the window with the higher level asm
    and place (or set snap) on a part. Rotate the part
    and note that the part does not honor the 30
    degree setting but rather is still honoring the 90
    degree setting.
    .
    PROBLEM:
    In the higher level assembly the parts are rotating
    in increments of 90 degrees but if you open the
    compass editor the setting is 30 degrees.
    .
    EXPECTED RESULT:
    Compass rotation should be honored.
    .
    

Local fix

Problem summary

  • ASD:Compass rotation increments not being honored
    ASD:Compass rotation increments not being
    honored
    .
    SCENARIO:
    1) Open any assembly that contains a sub
    assembly
    2) Set the compass rotation increments to 90
    degrees
    3) Place (or set snap) and rotate a part within the
    assembly. Note that the part honors the 90 degree
    setting.
    4) Open one of the sub assemblies from the higher
    level assembly in a New Window.
    5) Set the compass rotation increments to 30
    degrees
    6) Place (or set snap) and rotate a part within the
    sub assembly. Note that the part honors the 30
    degree setting.
    7) Return to the window with the higher level asm
    and place (or set snap) on a part. Rotate the part
    and note that the part does not honor the 30
    degree setting but rather is still honoring the 90
    degree setting.
    .
    PROBLEM:
    In the higher level assembly the parts are rotating
    in increments of 90 degrees but if you open the
    compass editor the setting is 30 degrees.
    .
    EXPECTED RESULT:
    Compass rotation should be honored.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 20 GA LEVEL.
    .
    INCIDENT DIAGNOSIS: When several windows are
    opened, compass values were transmitted from
    one window user interface to the others however
    they are not taken into account in the compass
    manipulations. Each window owns its compass but
    the values were stored in the compass panel as
    static variables, therefore each panel was not
    having its own values.
    .
    CORRECTION EXPLANATION: The correction has
    been done by removing the static declarations so
    that each panel will have its own values and values
    will not be transmitted from one window to other
    window.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD80937

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-12-23

  • Closed date

    2009-07-10

  • Last modified date

    2009-07-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following: