APAR status
Closed as program error.
Error description
Compo Design / Limit Contour / Can not select multiple sequence if ply has same name. . Scenario. . 1)Open the CATPart 2) Expand tree object Stacking(Engineering), expand tree object Plies Group.1. 3) In workbench Composite Design (CPD) select Insert/Plies/Limit Contour. In the Limit Contour Window open the Multi Selection Window for entity. 4) Select from the tree Sequence.2 and Sequence.3. In the Multi Selection Window Sequence.2 is listed only, Sequence.3 cannot be selected. Expected result: It should be possible to select Sequence.2 and Sequence.3 .
Local fix
Problem summary
Compo Design / Limit Contour / Can not select multiple sequence if ply has same name. Compo Design / Limit Contour / Can not select multiple sequence if ply has same name. . Scenario. . 1)Open the CATPart 2) Expand tree object Stacking(Engineering), expand tree object Plies Group.1. 3) In workbench Composite Design (CPD) select Insert/Plies/Limit Contour. In the Limit Contour Window open the Multi Selection Window for entity. 4) Select from the tree Sequence.2 and Sequence.3. In the Multi Selection Window Sequence.2 is listed only, Sequence.3 cannot be selected. Expected result: It should be possible to select Sequence.2 and Sequence.3 .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 20 GA LEVEL. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19SP04 Incident Diagnosis The Limit Contour command did not accept two different sequences if the their constituent plies had the same name. . Correction Explanation Previously, comparison to check if a selected entity for limit contour already existed was carried by means of name comparison. Now, code has been modified to check for spec objects thereby ensuring plies with same name but under different sequences are added to the multi-selection dialog box of the limit contour without any duplications. .
Temporary fix
Comments
APAR Information
APAR number
HD80422
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-12-04
Closed date
2009-03-02
Last modified date
2009-03-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 March 2009