Error description
V4-V5,The Chamfer figuration is different SCENARIO: 1. Launch CATIA V5. 2. File/Open the model the provided model 3. RMB on *Master and select Copy 4. Select File/New(PART) 5. Part1 is chosen and MB3 6. Paste Special / CATIA SPEC RESULT: Error message "Update Error for CHAM3, Chamfer.4 (CHAM3) : [Sick Features : None. Message : Ribbon Computation : Impossible Relimitation" occurs. The shape of the chamfer is not correct after migration. One chamfer feature in V4 is migrated as 4 chamfer features in V5 EXPECTED RESULT: 1. One chamfer feature in V4 should be migrated as one chamfer feature in V5. 2. The shape of the chamfer should be correct after migration .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT FOR CATIA. PLEASE CONTACT YOUR SUPPORT DEPARTMENT IN ORDER TO OPEN A REQUIREMENT FORM. . INCIDENT DIAGNOSIS One V4 chamfer does not give one V5 chamfer but multiple chamfers. . DEVELOPMENT REQUEST JUSTIFICATION The specs of V4 chamfer are different from the V5 chamfer. The V4V5 conversion takes each V4 edge, with its own chamfer parameters, and creates one V5 chamfer on each V4 edge. Such V5 chamfer are "independant" features and, as a consequence, for the IR, are not trimmed between themselves. New development is required to group the V4 edges which have the same chamfer parameters into a unique V5 chamfer. Then, this V5 chamfer featurewill be able to trim / relimit its internal surfaces and so on. In the model with this APAR, the V4 chamfer is made of 4 V4 edges with the same chamfer parameters : because they have the same parameters they can all be "grouped" into a unique V5 chamfer (with a unique parameter set, applied to all V5 chamfer edges). But this "grouping analysis" of V4 edges according to their own chamfer parameters needs new code development. This is why the APAR has been closed as SUG. However, if a V4 chamfer is made of 5 edges with 5 different parameter sets, it will be impossible to group them in an unique V5 chamfer, and there will still be 5 V5 Chamfers. This will be made available in R19 and V6R2010. NOT IN R18. .
APAR Information
APAR number
HD78004
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
518
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-09-18
Closed date
2008-10-14
Last modified date
2008-10-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
14 October 2008