  • KWA:THE VALUE OF PARAMETER CHANGES TO
    <UNSET>
    .
    SCENARIO:
    1) Start CATIA.
    2) Open the CATPart.
    Workbench: Generative Shape Design.
    3) Expand Parameters on the tree.
    Length.1 and Length.2 are displayed on the tree.
    4) Expand Relations on the tree.
    Confirm that Length.2 is using Point.3 of
    deactivation.
    5) Right Click on Point.3 on the tree and Activate
    Point.3
    Point.3 is activated
    6) Right Click on Point.3 on the tree and Deactivate
    Point.3.
    Point.3 is deactivated.
    7) Double-click Length.1 in the parameter.
    Edit Parameter dialog box is displayed.
    8) Change the value from 25mm to 28mm.
    9) Click OK.
    The value of Length.2 remains 30mm.
    10) Close this file without save.
    11) Open the CATPart again.
    Workbench: Generative Shape Design.
    14) Expand Parameters on the tree.
    Length.1 and Length.2 are displayed on the tree.
    15) Double-click Length.1.
    Edit Parameter dialog box is displayed.
    16) Change the value from 25mm to 28mm.
    17) Click OK.
    .
    PROBLEM:
    Error is displayed- Invalid input value and the
    value of Length.2 changes to Unset.
    .
    

Local fix

Problem summary

  • KWA:THE VALUE OF PARAMETER CHANGES TO UNSET
    KWA:THE VALUE OF PARAMETER CHANGES TO
    <UNSET>
    .
    SCENARIO:
    1) Start CATIA.
    2) Open the CATPart.
    Workbench: Generative Shape Design.
    3) Expand Parameters on the tree.
    Length.1 and Length.2 are displayed on the tree.
    4) Expand Relations on the tree.
    Confirm that Length.2 is using Point.3 of
    deactivation.
    5) Right Click on Point.3 on the tree and Activate
    Point.3
    Point.3 is activated
    6) Right Click on Point.3 on the tree and Deactivate
    Point.3.
    Point.3 is deactivated.
    7) Double-click Length.1 in the parameter.
    Edit Parameter dialog box is displayed.
    8) Change the value from 25mm to 28mm.
    9) Click OK.
    The value of Length.2 remains 30mm.
    10) Close this file without save.
    11) Open the CATPart again.
    Workbench: Generative Shape Design.
    14) Expand Parameters on the tree.
    Length.1 and Length.2 are displayed on the tree.
    15) Double-click Length.1.
    Edit Parameter dialog box is displayed.
    16) Change the value from 25mm to 28mm.
    17) Click OK.
    .
    PROBLEM:
    Error is displayed- Invalid input value and the
    value of Length.2 changes to Unset.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 20 GA LEVEL.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R19SP04
    .
    Incident Diagnosis: Inconsistent behavior when
    value of parameter is changed to Unset after
    related parameter is changed.
    .
    Correction Explanation:
    Value of parameter is changed to Unset when
    related parameter is changed because one of the
    input is deactivated Hence value of dependent
    parameter is not computed and changed to Unset.
    This is normal behavior.
    The behavior where value of parameter was not
    changing to Unset was the wrong behavior. Now
    the correction has been done so that after
    deactivating the input, parameter value will be
    changed to Unset.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD77393

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-08-27

  • Closed date

    2009-02-12

  • Last modified date

    2009-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN SP51904

       UP09/05/06 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
06 May 2009