APAR status
Closed as program error.
Error description
KWA:THE VALUE OF PARAMETER CHANGES TO <UNSET> . SCENARIO: 1) Start CATIA. 2) Open the CATPart. Workbench: Generative Shape Design. 3) Expand Parameters on the tree. Length.1 and Length.2 are displayed on the tree. 4) Expand Relations on the tree. Confirm that Length.2 is using Point.3 of deactivation. 5) Right Click on Point.3 on the tree and Activate Point.3 Point.3 is activated 6) Right Click on Point.3 on the tree and Deactivate Point.3. Point.3 is deactivated. 7) Double-click Length.1 in the parameter. Edit Parameter dialog box is displayed. 8) Change the value from 25mm to 28mm. 9) Click OK. The value of Length.2 remains 30mm. 10) Close this file without save. 11) Open the CATPart again. Workbench: Generative Shape Design. 14) Expand Parameters on the tree. Length.1 and Length.2 are displayed on the tree. 15) Double-click Length.1. Edit Parameter dialog box is displayed. 16) Change the value from 25mm to 28mm. 17) Click OK. . PROBLEM: Error is displayed- Invalid input value and the value of Length.2 changes to Unset. .
Local fix
Problem summary
KWA:THE VALUE OF PARAMETER CHANGES TO UNSET KWA:THE VALUE OF PARAMETER CHANGES TO <UNSET> . SCENARIO: 1) Start CATIA. 2) Open the CATPart. Workbench: Generative Shape Design. 3) Expand Parameters on the tree. Length.1 and Length.2 are displayed on the tree. 4) Expand Relations on the tree. Confirm that Length.2 is using Point.3 of deactivation. 5) Right Click on Point.3 on the tree and Activate Point.3 Point.3 is activated 6) Right Click on Point.3 on the tree and Deactivate Point.3. Point.3 is deactivated. 7) Double-click Length.1 in the parameter. Edit Parameter dialog box is displayed. 8) Change the value from 25mm to 28mm. 9) Click OK. The value of Length.2 remains 30mm. 10) Close this file without save. 11) Open the CATPart again. Workbench: Generative Shape Design. 14) Expand Parameters on the tree. Length.1 and Length.2 are displayed on the tree. 15) Double-click Length.1. Edit Parameter dialog box is displayed. 16) Change the value from 25mm to 28mm. 17) Click OK. . PROBLEM: Error is displayed- Invalid input value and the value of Length.2 changes to Unset. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 20 GA LEVEL. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19SP04 . Incident Diagnosis: Inconsistent behavior when value of parameter is changed to Unset after related parameter is changed. . Correction Explanation: Value of parameter is changed to Unset when related parameter is changed because one of the input is deactivated Hence value of dependent parameter is not computed and changed to Unset. This is normal behavior. The behavior where value of parameter was not changing to Unset was the wrong behavior. Now the correction has been done so that after deactivating the input, parameter value will be changed to Unset. .
Temporary fix
Comments
APAR Information
APAR number
HD77393
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-08-27
Closed date
2009-02-12
Last modified date
2009-05-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN SP51904