IBM Support

HD76053: VPMV5NAV : ATTACHING DOCUMENT TO PART REFERENCE REQUIRES TO LOC K ITEM INSTANCE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • Prob:
    Attaching Document to Part Reference requires to
    lock Item Instance.
    Preparation:
    Prep1
    Create and save 2 Explode Products instantiated to
    one PRC and 1 Document as follows in ENOVIA V5
    VPM.
    Prep2
    Prerequisites
    -Item Instance of OnlyInsLock.1 is locked by
    current user. And Part Version of OnlyInsLock is
    not locked.
    -Item Instance of OnlyRefLock.1 is not locked. And
    Part Version of OnlyRefLock is by current user.
    .
    Operation:
    Step1 Right-Mouse-Click OnlyInslock from VPM
    Navigator tree, and then select Attach Document
    command from contextual menu.
    Step2 Select options as follows:
    Link Type: Representation
    Parent Type: Reference
    Document Role: Supplementary
    Step3 Search for DocAttachedToReference, select
    it from Search Results, and then click Attach
    button.
    Step4 Document is attached to Part Version in spite
    that Part Version is not locked.
    Step5 Right-Mouse-Click OnlyReflock from VPM
    Navigator tree, and then take the same steps from
    2 to 6 as the previous slide.
    .
    Result:
    Document is NOT attached to Part Version even
    though Part Version is locked by the current user.
    .
    Expected result:
    At Step 4, Document should not be attached to Part
    Version because target Part Version is not locked.
    At Step 6, Document should be attached to Part
    Version because target Part Version is locked by
    the current user.
    .
    .
    

Local fix

Problem summary

  • VPMV5NAV : ATTACHING DOCUMENT TO PART REFERENCE REQUIRES TO LOC
    K ITEM INSTANCE.
    Prob:
    Attaching Document to Part Reference requires to
    lock Item Instance.
    Preparation:
    Prep1
    Create and save 2 Explode Products instantiated to
    one PRC and 1 Document as follows in ENOVIA V5
    VPM.
    Prep2
    Prerequisites
    -Item Instance of OnlyInsLock.1 is locked by
    current user. And Part Version of OnlyInsLock is
    not locked.
    -Item Instance of OnlyRefLock.1 is not locked. And
    Part Version of OnlyRefLock is by current user.
    .
    Operation:
    Step1 Right-Mouse-Click OnlyInslock from VPM
    Navigator tree, and then select Attach Document
    command from contextual menu.
    Step2 Select options as follows:
    Link Type: Representation
    Parent Type: Reference
    Document Role: Supplementary
    Step3 Search for DocAttachedToReference, select
    it from Search Results, and then click Attach
    button.
    Step4 Document is attached to Part Version in spite
    that Part Version is not locked.
    Step5 Right-Mouse-Click OnlyReflock from VPM
    Navigator tree, and then take the same steps from
    2 to 6 as the previous slide.
    .
    Result:
    Document is NOT attached to Part Version even
    though Part Version is locked by the current user.
    .
    Expected result:
    At Step 4, Document should not be attached to Part
    Version because target Part Version is not locked.
    At Step 6, Document should be attached to Part
    Version because target Part Version is locked by
    the current user.
    .
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON ENOVIA
    VERSION 5 RELEASE 18.
    THIS PROBLEM IS NOT REPRODUCIBLE ON ENOVIA
    VERSION 5 RELEASE 20 GA LEVEL.
    AND ON 19 SP01,V5R18SP07.
    .
    

APAR Information

  • APAR number

    HD76053

  • Reported component name

    ENOVIA V5 VPM A

  • Reported component ID

    569101400

  • Reported release

    518

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-07-10

  • Closed date

    2008-07-11

  • Last modified date

    2008-10-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA V5 VPM A

  • Fixed component ID

    569101400

Applicable component levels

  • R518 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7P2G","label":"ENOVIA V5 VPM Discipline"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
29 October 2008