IBM Support

HD75552: AEROSPACE SHEET METAL DESIGN : JOGGLE COMPENSATION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • AEROSPACE SHEET METAL DESIGN : JOGGLE
    COMPENSATION VALUE IS DISREGARDED
    Scenario:
    1. Open CATPart
    2. Change to Aerospace Sheet Metal Design work
    bench
    3. Select Fold/Unfold Icon in Aerospace Sheet Metal
    tool bar
    4. Measure the compensation amount in the flat
    view (Value
    measures 1.66 in) Compensation length should not
    exceed the
    value in the Method1.txt document (1.5 in)
    5. Change Plane 4 value to 9 inches
    Error Message Corner operator: Impossible to
    compute
    eventual center of corner between element 1 &
    element 2 edges.
    6. Select OK
    7. Select Cancel
    8. Double Click on Surfacic
    Flange.1+Compensation tab
    Uncheck the Apply Compensation tab
    9. Change Plane 4 value to 9 inches
    10. Part is now created with no compensation.
    The joggle compensation value should be limited to
    the value in
    the Method1. txt design table. The value in the
    included design
    table is 1.50 inches. Currently the compensation is
    applied the
    entire length between the joggle planes. If the
    second joggle
    plane is increased to a large distance CATIA will
    not build the
    part when joggle compensations are applied.
    .
    

Local fix

Problem summary

  • AEROSPACE SHEET METAL DESIGN : JOGGLE COMPENSATION
    VALUE IS DISREGARDED
    AEROSPACE SHEET METAL DESIGN : JOGGLE
    COMPENSATION VALUE IS DISREGARDED
    Scenario:
    1. Open CATPart
    2. Change to Aerospace Sheet Metal Design work
    bench
    3. Select Fold/Unfold Icon in Aerospace Sheet Metal
    tool bar
    4. Measure the compensation amount in the flat
    view (Value
    measures 1.66 in) Compensation length should not
    exceed the
    value in the Method1.txt document (1.5 in)
    5. Change Plane 4 value to 9 inches
    Error Message Corner operator: Impossible to
    compute
    eventual center of corner between element 1 &
    element 2 edges.
    6. Select OK
    7. Select Cancel
    8. Double Click on Surfacic
    Flange.1+Compensation tab
    Uncheck the Apply Compensation tab
    9. Change Plane 4 value to 9 inches
    10. Part is now created with no compensation.
    The joggle compensation value should be limited to
    the value in
    the Method1. txt design table. The value in the
    included design
    table is 1.50 inches. Currently the compensation is
    applied the
    entire length between the joggle planes. If the
    second joggle
    plane is increased to a large distance CATIA will
    not build the
    part when joggle compensations are applied.
    .
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19SP01
    AND ON R20GA
    Incident Diagnosis
    JOGGLE COMPENSATION VALUE IS DISREGARDED
    Correction Explanation
    An error has been found in the CATIA code during
    the compensation check.The feature is now
    corrected
    Answer and By-Pass
    The 2 Joggles must be deleted and re-created
    because this correction is versionned to ensure
    existing topology stability.
    The problem is not fixed on r18 because it modified the
    UnFolded result of the Surfacic Flange and should be
    versionned. The versionning is no more available on r18
    because r19 is now GA.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD75552

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-06-25

  • Closed date

    2008-09-04

  • Last modified date

    2008-09-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 September 2008