APAR status
Closed as program error.
Error description
Machining (NCInfra) / Error message "This Handler is Null" when trying to associate APT file to NC program. . SCENARIO: Please see the video file attached for scenario. . EXPECTED RESULT: The present error should not be displayed. . .
Local fix
Problem summary
Machining (NCInfra) / Error message "This Handler is Null" when trying to associate APT file to NC program. Machining (NCInfra) / Error message "This Handler is Null" when trying to associate APT file to NC program. . SCENARIO: Please see the video file attached for scenario. . EXPECTED RESULT: The present error should not be displayed. . .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 20 GA LEVEL. . Incident Diagnosis This Handler is Null' when trying to associate APT file to NC program. . Correction Explanation The APT reader was trying to set the RAPID feedrate even though there was no tool-path. . Answer and By-Pass None . Additional Information: This will be also fixed on R19SP1. .
Temporary fix
Comments
APAR Information
APAR number
HD74981
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-06-05
Closed date
2008-06-23
Last modified date
2008-06-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN