Error description
ABSTRACT: CV5: Cannot open 2 Products in different CATIA Windows from 1 PSN. . SCENARIO: 1. Open a simple assembly in a PSN, select one CATIA V5 3d document,select 'Open selected model in CATIA V5' and open the document with the option 'Open in a new CATIA V5 Product' . 2. Select a second CATIA V5 document,select 'Open selected model in CATIA V5' and open the document with the option 'Open in a new CATIA V5 Product'. . RESULT:- An error message occur, to open 2 CATIA V5 windows from the same PSN is not possible . ==> Error message: . CNEXT - CATEnoviaErrors - ERR_0217 . "The Document xyz (Enovia VPM) is already open or loaded in the session. Close all documents in Catia first and then reopen from VPM"OK. .
Local fix
Problem summary
Cannot open 2 Products in different CATIA Windows from 1 PSN ABSTRACT: CV5: Cannot open 2 Products in different CATIA Windows from 1 PSN. . SCENARIO: 1. Open a simple assembly in a PSN, select one CATIA V5 3d document,select 'Open selected model in CATIA V5' and open the document with the option 'Open in a new CATIA V5 Product' . 2. Select a second CATIA V5 document,select 'Open selected model in CATIA V5' and open the document with the option 'Open in a new CATIA V5 Product'. . RESULT:- An error message occur, to open 2 CATIA V5 windows from the same PSN is not possible . ==> Error message: . CNEXT - CATEnoviaErrors - ERR_0217 . "The Document xyz (Enovia VPM) is already open or loaded in the session. Close all documents in Catia first and then reopen from VPM"OK. .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON CATIA VERSION 5 RELEASE 18. THIS PROBLEM IS NOT REPRODUCIBLE ON CATIA VERSION 5 RELEASE 19 GA LEVEL. AND ON V5R18SP06 . Incident Diagnosis: CV5: Cannot open 2 Products in different CATIA Windows from 1 PSN . Answer and By-Pass: To correct this behaviour the following CV5 Environment variable should be exported: CV5_VPM_ALLOWSAMEROOTPRD=1 .
APAR Information
APAR number
HD74938
Reported component name
CATIA V5 HP-UX
Reported component ID
569102000
Reported release
518
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-06-04
Closed date
2008-06-06
Last modified date
2008-08-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 HP-UX
Fixed component ID
569102000
Applicable component levels
R518 PSN SP51866
UP08/08/19 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
28 August 2008