APAR status
Closed as unreproducible in next release.
Error description
ASMD : CUTOUT : CUTOUT FAILS WITH TRIM BY THICK OPERATOR ERROR ON UPDATING R14 CATPART TO R18 . SCENARIO: 1. Open supplied CATPart. 2. Double click on Sketch.1. Sketcher workbench appears 3. Create a point and delete the same. 4. Exit sketcher . OBSERVATION: Cutout.1 fails with error - Trim by Thick operator: The result cannot be assembled because of a current or permanent restriction. Change value or modify input body. Trim by Thick operator: Offset failed for sharp edges locally smooth (fading edges). Smooth input body in the neighborhood of these edges or trim tangency area. .
Local fix
Problem summary
ASMD : CUTOUT : CUTOUT FAILS WITH TRIM BY THICK OPERATOR ERROR ON UPDATING R14 CATPART TO R18 ASMD : CUTOUT : CUTOUT FAILS WITH TRIM BY THICK OPERATOR ERROR ON UPDATING R14 CATPART TO R18 . SCENARIO: 1. Open supplied CATPart. 2. Double click on Sketch.1. Sketcher workbench appears 3. Create a point and delete the same. 4. Exit sketcher . OBSERVATION: Cutout.1 fails with error - Trim by Thick operator: The result cannot be assembled because of a current or permanent restriction. Change value or modify input body. Trim by Thick operator: Offset failed for sharp edges locally smooth (fading edges). Smooth input body in the neighborhood of these edges or trim tangency area. .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON CATIA VERSION 5 RELEASE 18. THIS PROBLEM IS NOT REPRODUCIBLE ON CATIA VERSION 5 RELEASE 20 GA LEVEL. V5R19SP01 AND ON V5R18SP06 . Incident Diagnosis CUTOUT FAILS WITH TRIM BY THICK OPERATOR ERROR ON UPDATING R14 CATPART TO R18 . For cutout failure : The cutout feature mapping fails for closed sketch. A closed sketch leads Instabilities (boundary conditions). So in order to by-pass these instabilities edited all cutout input sketches and remove the projections (borders edges) used to create a closed sketch. . Answer and By-Pass Modify the sketches used for all cutout to remove the projections, which form closed profile .
APAR Information
APAR number
HD74780
Reported component name
CATIA V5 HP-UX
Reported component ID
569102000
Reported release
518
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-05-30
Closed date
2008-05-30
Last modified date
2008-08-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 HP-UX
Fixed component ID
569102000
Applicable component levels
R518 PSN SP51866
UP08/08/19 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
28 August 2008