APAR status
Closed as unreproducible in next release.
Error description
Scenario: 1- File / Open the provided CATProduct 4100057146C01_DRW_C5B.CATProduct - A message displays to say that a CATPart is missing. But if the Desk is checked, no CATPart is missing, so it could be a ghost link. 2- you can not switch from visualisation to design mode. 3 -Execute CATDUA batch on on all CATParts and CATProducts and one additional interactive CATDUA (from desk within CATIA, on top-level- node) it is possible to switch into design mode. . To have the white axis icon appear it is necessary to select the part node. To switch this part or instance into design mode and restore visibility it is necessary to double-click or use the context menu. . 4. Load assembly in CATIA an execute CATDUA from "Desk" (interactive, on top level node). => After executing the final CATDUA interactively, it is possible to switch the part instances into Design Mode. ==> Why does CATDUA not clean all errors? - Is the difference between interactive and batch CATDUA documented? - Why is it necessary to restore the part instance status by manual interaction? . .
Local fix
Problem summary
ASD : CATDUA V5 OERATION IS UNSUCCESSFULL BECAUSE IT IS NOT POS SIBLE TO SWITCH INTO DESIGN MODE Scenario: 1- File / Open the provided CATProduct 4100057146C01_DRW_C5B.CATProduct - A message displays to say that a CATPart is missing. But if the Desk is checked, no CATPart is missing, so it could be a ghost link. 2- you can not switch from visualisation to design mode. 3 -Execute CATDUA batch on on all CATParts and CATProducts and one additional interactive CATDUA (from desk within CATIA, on top-level- node) it is possible to switch into design mode. . To have the white axis icon appear it is necessary to select the part node. To switch this part or instance into design mode and restore visibility it is necessary to double-click or use the context menu. . 4. Load assembly in CATIA an execute CATDUA from "Desk" (interactive, on top level node). => After executing the final CATDUA interactively, it is possible to switch the part instances into Design Mode. ==> Why does CATDUA not clean all errors? - Is the difference between interactive and batch CATDUA documented? - Why is it necessary to restore the part instance status by manual interaction? . .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON CATIA VERSION 5 RELEASE 18. THIS PROBLEM IS NOT REPRODUCIBLE ON CATIA VERSION 5 RELEASE 19 SP01 LEVEL. . Incident Diagnosis: Some Part Instances were not able to Switch from Visu mode to Design Mode. . Reason: In this APAR the root cause was in 1000107939C01_DCA_C5P.CATPart. . The broken part instance has its reference in respective CATPart. But they does not contain the desired ProdCont. . The UUID on the link is different that of the one in the part. . For example, Removing the original ABCD.CATPart file and renaming another one to ABCD.CATPart or Manipulations of CATPart directly under File Manager (maybe by the user of non DS PDM system): might generate this type of issue. . In such cases, our recommendation is to use the interactive Replace command to change a CATPart by another one. i.e for this APAR to fix , we just need to Replace the respective instance by corresponding CATPart (using Edit->Links) - and then do File ->Desk -> CATDUA . . This makes the scenario UR. . NOW Regarding the Queries, a. Why does CATDUA not clean all errors? Please check the documentation mentioned below to check the limitations on CATDUA. . b.Is the difference between interactive and batch CATDUA documented? Answer : The link shows the difference in using CATDUA in batch as well as Desk. See CATIA Infrastructure User Guide / Running Batches / Using the CATDUAV5 in the CATIA V5 documentation . c.Why is it necessary to restore the part instance status by manual interaction? Answer: this is the available solution to interactively select and update the broken part instance link. which otherwise cannot be known by catia itself. . .
APAR Information
APAR number
HD74375
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-05-16
Closed date
2008-07-29
Last modified date
2008-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN SP51901
UP08/10/03 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
03 October 2008