APAR status
Closed as user error.
Error description
Changing the value of "Display all elements using Z-buffer depth" in CAA code. . Scenario 1. compile attached work space and start up CATIA. 2. new Part and execut the command "ChangeToolsOptions". 3. open "Tools->Options->Display->Visualization" dialog. 4. the "Display all elements using Z-buffer depth" Value is not changed. 5. click Cancel 6. open again "Tools->Options->Display->Visualization" dialog. -> All is OK, value is changed. . I tried to change value of the parameter Tools -> Options -> Display -> Visualization -> Display all elements using Z-buffer but it doesn't work properly. .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
This is an User Error. . .Incident Diagnosis When using CATSettingRepository method (WriteSetting) the Tools/Option panel is not updated because in this case only the setting repository is updated. User should not modify the Visu setting value out of Tools/Option. . .Correct Application If it is really necessary, user should use the appropriated interfaces: - CATIAVisualizationSettingAtt.idl (for automation) - CATIAVisualizationSettingAtt.h (for C++) . .Documentation Reference CATIA Infrastructure User Guide Getting Started - .
APAR Information
APAR number
HD73731
Reported component name
CAA V5 NT>XP
Reported component ID
569151100
Reported release
518
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2008-04-22
Closed date
2008-06-12
Last modified date
2008-06-12
APAR is sysrouted FROM one or more of the following: