WARM START: WARM START FAILS AND CATIA IS FORCED TO TERMINATE. . SETTINGS: Set 'Incremental backup' to ON. . SCENARIO: 0. Start CATIA. 1. Open the file: 'TOP.CATProduct'. Workbench: 'Product Structure'. 2. Double click '02' on the tree. '02' is activated. Workbench changed to GSD. 3. Click 'Point' on the tool bar. 'Point Definition' dialog box is displayed. And click 'OK'. 'Point.1' is created. 4. Open the file: 'P00273.CATPart'. Workbench: Generative Shape Design. 5. Click 'Corner' on the tool bar. 'Corner Definition' dialog box is displayed. Refer to the value of set up below. Corner Type: 3D Corner Element 1: Curve.1 Element 2: Curve.2. 'Runtime exception' dialog box is displayed. And click 'OK'. CATIA is forced to terminate. 7. Restart CATIA. 8. 'Warm-start' dialog box is displayed. And click 'OK'. Warm start starts. 'Warm start fail message' is displayed. And click 'OK'. CATIA is ended and the data edited on 'TOP.Product' is not restored. This is problem. . .
Local fix
Problem summary
WARM START: WARM START FAILS AND CATIA IS FORCED TO TERMINATE. WARM START: WARM START FAILS AND CATIA IS FORCED TO TERMINATE. . SETTINGS: Set 'Incremental backup' to ON. . SCENARIO: 0. Start CATIA. 1. Open the file: 'TOP.CATProduct'. Workbench: 'Product Structure'. 2. Double click '02' on the tree. '02' is activated. Workbench changed to GSD. 3. Click 'Point' on the tool bar. 'Point Definition' dialog box is displayed. And click 'OK'. 'Point.1' is created. 4. Open the file: 'P00273.CATPart'. Workbench: Generative Shape Design. 5. Click 'Corner' on the tool bar. 'Corner Definition' dialog box is displayed. Refer to the value of set up below. Corner Type: 3D Corner Element 1: Curve.1 Element 2: Curve.2. 'Runtime exception' dialog box is displayed. And click 'OK'. CATIA is forced to terminate. 7. Restart CATIA. 8. 'Warm-start' dialog box is displayed. And click 'OK'. Warm start starts. 'Warm start fail message' is displayed. And click 'OK'. CATIA is ended and the data edited on 'TOP.Product' is not restored. This is problem. . .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON CATIA VERSION 5 RELEASE 17. THIS PROBLEM IS NOT REPRODUCIBLE ON CATIA VERSION 5 RELEASE 19 GA LEVEL. AND ON V5R18SP05 .
APAR Information
APAR number
HD73690
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-04-21
Closed date
2008-04-22
Last modified date
2008-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R518 PSN SP51805
UP08/06/02 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 June 2008