IBM Support

HD72173: STCAI : NEW REVISION OPENED FROM SMARTEAM IS NOT RELOADED IN CA TIA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • STCAI : New revision opened from Smarteam is
    not reloaded in CATIA
    .
    CATIA Smarteam integration problem reproduced
    on SmDemo
    .
    Prereq:
    1. Launch Smarteam Editor
    Select Tools / Administrator Operations / Life Cycle
    Options.
    Select 'Out of Vault' Tab. Activate only the following
    options:
    'Copy general links on Check Out / New Release'
    'Replace local files on copy : Yes, when not in work'
    'Replace local files on check out/New Release : Yes'
    Click "Latest Revision" button.
    Activate "Always Check Out latest available
    revision"
    2. Select Tools/Application setup. Select CNEXT
    instead of CAIOPEN for opening the CATIA
    documents
    3. Activate the following environment variables for
    CATIA :
    FORCE_SYNCHRO_ON_OPEN=1
    SYNCHRO_REPAIR_ON_OPEN=1
    .
    Scenario:
    1. Start CATIA V5R17 and Smarteam V5R14.
    2. Create a new CATProduct with a sub CATProduct
    and a new CATPart in the sub CATProduct
    3. Save and check in in Smarteam the top
    CATProduct
    4. Open for edit the CATPart. Make a modification
    and check it in.
    5. Open for edit the top CATProduct
    6. Disconnect from Smarteam in CATIA
    7. In CATIA, 'open in new window' the CATPart
    8. In Smarteam editor, select the latest revision of
    the CATPart and select 'open'
    => The latest revision is copied to the work but not
    loaded in CATIA
    9. Connect to Smarteam in CATIA
    => The subproduct and the CATPart are now seen
    as dirty
    10. In CATIA, select Yes to the COOF. check out
    the CATProduct and check out also the CATPart
    Result : The latest revision of the CATPart is
    reloaded in CATIA and checked out.
    This is the expected result
    .
    Now, perform the same scenario with CATIA V5R17
    and Smarteam V5R17.
    At step 10, after the check out, the latest revision
    of the CATPart is not reloaded in CATIA and the old
    revision is checked out.
    This is the problem.
    .
    

Local fix

Problem summary

  • STCAI : New revision opened from Smarteam is not reloaded in CA
    TIA
    STCAI : New revision opened from Smarteam is
    not reloaded in CATIA
    .
    CATIA Smarteam integration problem reproduced
    on SmDemo
    .
    Prereq:
    1. Launch Smarteam Editor
    Select Tools / Administrator Operations / Life Cycle
    Options.
    Select 'Out of Vault' Tab. Activate only the following
    options:
    'Copy general links on Check Out / New Release'
    'Replace local files on copy : Yes, when not in work'
    'Replace local files on check out/New Release : Yes'
    Click "Latest Revision" button.
    Activate "Always Check Out latest available
    revision"
    2. Select Tools/Application setup. Select CNEXT
    instead of CAIOPEN for opening the CATIA
    documents
    3. Activate the following environment variables for
    CATIA :
    FORCE_SYNCHRO_ON_OPEN=1
    SYNCHRO_REPAIR_ON_OPEN=1
    .
    Scenario:
    1. Start CATIA V5R17 and Smarteam V5R14.
    2. Create a new CATProduct with a sub CATProduct
    and a new CATPart in the sub CATProduct
    3. Save and check in in Smarteam the top
    CATProduct
    4. Open for edit the CATPart. Make a modification
    and check it in.
    5. Open for edit the top CATProduct
    6. Disconnect from Smarteam in CATIA
    7. In CATIA, 'open in new window' the CATPart
    8. In Smarteam editor, select the latest revision of
    the CATPart and select 'open'
    => The latest revision is copied to the work but not
    loaded in CATIA
    9. Connect to Smarteam in CATIA
    => The subproduct and the CATPart are now seen
    as dirty
    10. In CATIA, select Yes to the COOF. check out
    the CATProduct and check out also the CATPart
    Result : The latest revision of the CATPart is
    reloaded in CATIA and checked out.
    This is the expected result
    .
    Now, perform the same scenario with CATIA V5R17
    and Smarteam V5R17.
    At step 10, after the check out, the latest revision
    of the CATPart is not reloaded in CATIA and the old
    revision is checked out.
    This is the problem.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    The methodology is not the correct one. The user
    must use 'replace with selected revision' in order to
    properly reload a revision in session
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD72173

  • Reported component name

    SMARTEAM NT>XP

  • Reported component ID

    569199970

  • Reported release

    517

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-03-06

  • Closed date

    2008-04-29

  • Last modified date

    2008-04-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
29 April 2008