APAR status
Closed as Permanent restriction.
Error description
ASD: PRODUCT LINK IS BROKEN WHEN SAVING A CATPART OVERWRITING ANOTHER CATPART WITH THE SAME NAME CONSISTING THE PRODUCT Scenario: Preparation: Set up Option as follows: Work with the Cache system is checked. Step1 Open TOP_PROD.CATProduct. Step2 Check that Link and a tree component are normal. Step3 Close TOP_PROD.CATProduct. Step4 Open BBB.CATPart. Step5 Save BBB.CATPart by the name of AAA.CATPart. Note:Please push Yes to that message to overwrite. Step6 Close BBB.CATPart. Step7 Open TOP_PROD.CATProduct. Step8 Expand tree. Result: It does not change to Design Mode. The link between Product and Part has broken. And CGR of changed CATpart is shown Expected Result: Broken links is expected behavior due to different UUID, but CGR of BBB.CATPart should not displayed. . .
Local fix
Problem summary
ASD: PRODUCT LINK IS BROKEN WHEN SAVING A CATPART OVERWRITING A NOTHER CATPART WITH THE SAME NAME CONSISTING THE PRODUCT ASD: PRODUCT LINK IS BROKEN WHEN SAVING A CATPART OVERWRITING ANOTHER CATPART WITH THE SAME NAME CONSISTING THE PRODUCT Scenario: Preparation: Set up Option as follows: Work with the Cache system is checked. Step1 Open TOP_PROD.CATProduct. Step2 Check that Link and a tree component are normal. Step3 Close TOP_PROD.CATProduct. Step4 Open BBB.CATPart. Step5 Save BBB.CATPart by the name of AAA.CATPart. Note:Please push Yes to that message to overwrite. Step6 Close BBB.CATPart. Step7 Open TOP_PROD.CATProduct. Step8 Expand tree. Result: It does not change to Design Mode. The link between Product and Part has broken. And CGR of changed CATpart is shown Expected Result: Broken links is expected behavior due to different UUID, but CGR of BBB.CATPart should not displayed. . .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Incident Diagnosis: When a part (say first part) is opened and SAVE AS by a same name of some other part (say second part), this second part belongs to a product. When this product has been opened in a CACHE mode ON, we are able to visualize in the workspace the first part (instead of second since it is overwritten by first). This first part cannot be turned to design mode since the links are broken and the part is not loaded due to different UUID. However if first part is not able to turned to design mode it should also not be visualize. Restriction Explanation: When this part is tried to change to design mode its part reference is unable to load because of different UUID (Unique Universal Identifier). However when a product is opened in a CGR mode, CATIA able to find instance reference link (information in the product aggregating the part instance) to decide its visualization, hence CATIA is able to find local Cache CGR is available and up to date; hence CGR is displayed. This is a limitation in CATIA. By-Pass Empty local cache. .
Temporary fix
Comments
APAR Information
APAR number
HD71813
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-02-21
Closed date
2008-04-04
Last modified date
2008-06-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
27 June 2008