IBM Support

HD71557: VISUALIZATION: IMAGE CAPTURE: PIXEL MODE SETTING NOT TAKEN INTO ACCOUNT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • VISUALIZATION: IMAGE CAPTURE: PIXEL MODE
    SETTING NOT TAKEN INTO ACCOUNT
    .
    SCENARIO:
    0) Start CATIA
    1) Open a new CATPart
    2) Go to Tools/Image/Capture
    3) In Capture window
    - select Pixel mode
    - select Options
    4) In Capture Options window click tab: Pixel
    - set Rendering Quality = Custom
    - select More button
    5) Window Image Size - move slider Resolution to
    increase resolution
    6) Select OK twice, to close the option windows
    7) Repeat step 03 and re-check the settings
    - OK to close option windows.
    8) In Capture window select the record button
    9) In Capture Preview window - Save the picture
    as .bmp file
    10) Now check the properties / file-info of your new
    generated .bmp file
    .
    PROBLEM:
    The user defined resolution setting is not kept.  It
    has been reset to minimum during the image
    record command.
    .
    

Local fix

Problem summary

  • VISUALIZATION: IMAGE CAPTURE: PIXEL MODE SETTING NOT TAKEN INTO
    ACCOUNT
    VISUALIZATION: IMAGE CAPTURE: PIXEL MODE
    SETTING NOT TAKEN INTO ACCOUNT
    .
    SCENARIO:
    0) Start CATIA
    1) Open a new CATPart
    2) Go to Tools/Image/Capture
    3) In Capture window
    - select Pixel mode
    - select Options
    4) In Capture Options window click tab: Pixel
    - set Rendering Quality = Custom
    - select More button
    5) Window Image Size - move slider Resolution to
    increase resolution
    6) Select OK twice, to close the option windows
    7) Repeat step 03 and re-check the settings
    - OK to close option windows.
    8) In Capture window select the record button
    9) In Capture Preview window - Save the picture
    as .bmp file
    10) Now check the properties / file-info of your new
    generated .bmp file
    .
    PROBLEM:
    The user defined resolution setting is not kept.  It
    has been reset to minimum during the image
    record command.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA LEVEL.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP05
    Incident Diagnosis:
    PIXEL MODE SETTING NOT TAKEN INTO
    ACCOUNTDURING IMAGE CAPTURE.
    .
    Correction Explanation:
    The resolution is now kept. It does not get reset
    during the image record command.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD71557

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-02-13

  • Closed date

    2008-03-24

  • Last modified date

    2008-03-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
24 March 2008