IBM Support

HD71271: ELECTRICAL (EHF) - ELECTRICAL SOFTWARE ERROR INSIDE THE FLATTEN COMMAND

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario :
    1- File / Open the CATProduct file
    2- Create a new Product and go to Electrical
    Harness Flattening workbench
    3- Define Flattening parameters
    4- Extract the model in the new CATProduct
    5- Flatten the 3D model with use of the "Select All
    Branches" command (select the fixed point at the
    begining of the harness)
    6- Select OK
    Result :
    The following error message appears :
    Electrical Software Error inside the Flatten
    command
    Expected Result :
    Flattening should be done without error message.
    .
    

Local fix

Problem summary

  • Electrical (EHF) - Electrical software error inside the flatten
    command
    Scenario :
    1- File / Open the CATProduct file
    2- Create a new Product and go to Electrical
    Harness Flattening workbench
    3- Define Flattening parameters
    4- Extract the model in the new CATProduct
    5- Flatten the 3D model with use of the "Select All
    Branches" command (select the fixed point at the
    begining of the harness)
    6- Select OK
    Result :
    The following error message appears :
    Electrical Software Error inside the Flatten
    command
    Expected Result :
    Flattening should be done without error message.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA LEVEL.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP04
    Incident Diagnosis
    The behavior is dependant on Extract option.
    With Extract New From, Extract is OK, Flatten is OK
    without Electrical Software Error, but there are
    some update errors on protections on doing Update
    after Flatten. There is one more problem - there is
    one support through which 3 BNSs are routed.
    After flatten, support remains on route of 1 BNS
    and green lines are created for showing links
    between the other 2 BNSs and this support. The
    position of green lines was incorrect.
    With Extract through Synchronize, Extract is OK,
    Flatten is OK and Update after Flatten is also OK.
    Though 5 protections are not extracted with this
    option and they are listed in the error table of the
    Extract html report. It is because they have broken
    external references in 3D Design.
    It is not possible to understand why some
    protections have broken external references or bad
    pointings to extremities.
    Correction Explanation
    Extract New From :
    A correction has been done to get the green lines
    at the good position.
    For update errors on protections after flatten, the
    reason is bad data for these protections in 3D
    Design. Some of these protections have broken
    external references and for others, their end point
    external references point to the wrong extremity
    point of wrong branchables (they point branchables
    which are not covered by this protection). Since
    the design data is bad, there is no way to correct
    this problem automatically during Extract New From
    + Flatten. The good way to correct this problem is
    explained in the by-pass section.
    Answer and By-Pass
    With option 'Extract New From' :
    On Update after Flatten, an update diagnostic
    comes. User can use center graph to find the
    protection having problem and then desactivate
    these protections. At the end these protections
    should be deleted from 3D Flatten view. This way
    the user gets the list of protections which have bad
    data in 3D Design. Then user can find these
    protections in 3D Design and correct them using
    edit protection command for example. Now, the
    design data is correct and user can simply use
    Synchronize command in 3D Flatten and these
    protections will be added in the 3D Flatten view.
    With 'Extract through Synchronize' :
    5 protections are not extracted and they are listed
    in the error table of Extract html report. User can
    correct these 5 protections in 3D Design. Once the
    3D Design is corrected, user can redo the Extract,
    or if he has already created the flattened layout, he
    can do Synchronize also to get these protections in
    3D Flatten view.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD71271

  • Reported component name

    CATIA V5 HP-UX

  • Reported component ID

    569102000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-02-04

  • Closed date

    2008-03-12

  • Last modified date

    2008-03-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 HP-UX

  • Fixed component ID

    569102000

Applicable component levels

  • R518 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 March 2008