HD70002: CRASH WHEN READING A CLASH DEFINITION WITH A CAA APPLICATION .

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • using a german XML file and importing it back in an
    english CATIA environment with a CAA application,
    gives a wrong collision value (get positive number
    instead of negative one).
    .
    Scenario:
    - Unzip the PMR12499.zip file in E:\tmp\PMR12499
    folder
    - Build the workspace E:\tmp\PMR12499\WS .
    - Run the generated batch (mkrun -c
    ClashtesterBatch.exe).
    .
    RESULT:
    Imported.CATProduct is created in the
    E:\tmp\PMR12499\Data\ folder. You will notice that
    a collision node is created, but the result is wrong.
    The clash result value is 9 (positive) instead of -9.3
    (negative) like it should be.
    .
    

Local fix

Problem summary

  • Crash when reading a clash definition with a CAA application
    using a german XML file and importing it back in an
    english CATIA environment with a CAA application,
    gives a wrong collision value (get positive number
    instead of negative one).
    .
    Scenario:
    - Unzip the PMR12499.zip file in E:\tmp\PMR12499
    folder
    - Build the workspace E:\tmp\PMR12499\WS .
    - Run the generated batch (mkrun -c
    ClashtesterBatch.exe).
    .
    RESULT:
    Imported.CATProduct is created in the
    E:\tmp\PMR12499\Data\ folder. You will notice that
    a collision node is created, but the result is wrong.
    The clash result value is 9 (positive) instead of -9.3
    (negative) like it should be.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA level.
    .
    .Incident Diagnosis
    When an xml for the clash is generated on a
    computer with German lang and imported on a
    computer with English lang., the results is not
    correct.
    .Correction Explanation
    Added a new attribute ResultTypeNoNLS in the xml
    of the clash. While importing the xml, this attribute
    will be read if it is present, otherwise the attribute
    ResultType will be read.
    .Answer and By-Pass
    None.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD70002

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-12-14

  • Closed date

    2008-02-20

  • Last modified date

    2009-08-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R516 PSN

       UP

  • R518 PSN

       UP

  • R517 PSN

       UP