IBM Support

HD69389: PART: EQUIVALENT DIMENSIONS: THE VALUES OF DIMENSIONS IN THE S KETCH ARE NOT KEPT WHEN ADDED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • PART:  EQUIVALENT DIMENSIONS: THE VALUES OF
    DIMENSIONS IN THE SKETCH ARE NOT KEPT WHEN
    ADDED.
    .
    SCENARIO.
    1. Start CATIA V5R17SP06. Refer to the .ppt file
    attched.
    2. Open file: Part1.CATPart .
    3. Double click Sketch.1.
    4. Click Constraint icon and select the horizontal
    line.
    5. Click Constraint icon and select the vertical line.
    6. Exit from the sketcher.
    7. Click Equivalent Dimensions icon. Equivalent
    Dimensions feature Edition dialog box is
    displayed.
    8. Click Edit List button. Choose the parameters for
    the Equivalent Dimensions feature dialog box is
    displayed and two Length is dispalyed in
    Parameters list.
    9. Select the two length parameters.
    10. Click Adds the selected parameters in the
    parameters of the Equivalent Dimensions button.
    Two length parameters move from Parameters list
    box to Parameters for Equivalent Dimensions list
    box.
    11. Click OK. Back to Equivalent Dimensions
    feature Edition dialog box. But values of the two
    length parameters become 0mm. This is the
    problem.
    Error: Values of the dimensions of the Sketch are
    not kept when they are added to Equivalent
    Dimensions operation.
    .
    .
    

Local fix

Problem summary

  • PART:  EQUIVALENT DIMENSIONS: THE VALUES OF DIMENSIONS IN THE S
    KETCH ARE NOT KEPT WHEN ADDED.
    PART:  EQUIVALENT DIMENSIONS: THE VALUES OF
    DIMENSIONS IN THE SKETCH ARE NOT KEPT WHEN
    ADDED.
    .
    SCENARIO.
    1. Start CATIA V5R17SP06. Refer to the .ppt file
    attched.
    2. Open file: Part1.CATPart .
    3. Double click Sketch.1.
    4. Click Constraint icon and select the horizontal
    line.
    5. Click Constraint icon and select the vertical line.
    6. Exit from the sketcher.
    7. Click Equivalent Dimensions icon. Equivalent
    Dimensions feature Edition dialog box is
    displayed.
    8. Click Edit List button. Choose the parameters for
    the Equivalent Dimensions feature dialog box is
    displayed and two Length is dispalyed in
    Parameters list.
    9. Select the two length parameters.
    10. Click Adds the selected parameters in the
    parameters of the Equivalent Dimensions button.
    Two length parameters move from Parameters list
    box to Parameters for Equivalent Dimensions list
    box.
    11. Click OK. Back to Equivalent Dimensions
    feature Edition dialog box. But values of the two
    length parameters become 0mm. This is the
    problem.
    Error: Values of the dimensions of the Sketch are
    not kept when they are added to Equivalent
    Dimensions operation.
    .
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
    CATIA VERSION 5 RELEASE 17.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    CATIA VERSION 5 RELEASE 19 GA level.
    .
    Incident Diagnosis.
    Values of the dimensions of the Sketch were not
    kept when they are added to Equivalent
    Dimensions operation. Due to this problem the
    feature like Pad created by this sketch fails and
    gives update error message. Also when the new
    value is inputted in the Equivalent Dimension dialog
    box the orientation of the skecth changes.
    .
    Reason.
    Now the values of the dimensions of the sketch are
    kept while adding them to Equivalent Dimensions.
    Hence all the above problems does not occur.
    .
    This problem is reproducible on V5R17 SP07 level
    however this problem is not reproducible on the
    above mentioned level.
    .
    Also note this problem is not reproducible on
    V5R18 SP02 level onwards.
    .
    .
    

APAR Information

  • APAR number

    HD69389

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-11-21

  • Closed date

    2007-11-22

  • Last modified date

    2007-11-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
22 November 2007