IBM Support

HD69349: PART: CATALOG BROWSER: DESIGN TABLE IS NOT LINKED TO UDF

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • PART: CATALOG BROWSER: DESIGN TABLE IS
    NOT LINKED TO UDF
    .
    SCENARIO:
    1) Start CATIA.
    2) Open catalog browser, select Gravure.catalog
    (in "SubFolder") and instantiate the UDF:
    Gravure / FormeED
    .
    PROBLEM:
    In the instantiation panel, edit parameters: the
    table is no more linked to the UDF. We can put
    values which are not defined in the table.
    .
    

Local fix

Problem summary

  • PART: CATALOG BROWSER: DESIGN TABLE IS NOT LINKED TO UDF
    PART: CATALOG BROWSER: DESIGN TABLE IS
    NOT LINKED TO UDF
    .
    SCENARIO:
    1) Start CATIA.
    2) Open catalog browser, select Gravure.catalog
    (in "SubFolder") and instantiate the UDF:
    Gravure / FormeED
    .
    PROBLEM:
    In the instantiation panel, edit parameters: the
    table is no more linked to the UDF. We can put
    values which are not defined in the table.
    .
    

Problem conclusion

  • THIS MODIFICATION WILL BE INCLUDED IN CATIA
    DOCUMENTATION DELIVERED WITH CATIA
    VERSION 5 RELEASE 19.
    NOTE THAT DOCUMENTATION WILL ALSO BE
    INCLUDED IN V5R18SP03.
    .
    Documentation Reference
    CATIA Infrastructure / Advanced Tasks / About
    Design Tables
    .
    MODIFICATION:
    New text added in the above mentioned topic:
    "When loading CATIA document containing design
    table linked to an external file (excel file or
    tabulated text file), the system tries to resolve the
    links to provide access to these external files. To
    ensure this, you need to define different link
    resolution strategies in Tools > Options > General
    > Document tab, Linked Document Localization
    area. For more information on this setting, see
    CATIA Infrastructure's User Guide: Customizing:
    Document.
    With no strategy defined or improper strategy, the
    design table is unable to locate the external file.
    This results in the following behavior:
    - You can add or edit parameters values which are
    not defined in the table.
    - Every time you modify the parameters, the
    Knowledge Report warning message is displayed,
    insisting you to define a strategy under Linked
    Document Localization.
    If you want to be sure that the link will be resolved,
    activate the option Folder of the link in the Linked
    Document Localization."
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD69349

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-11-20

  • Closed date

    2007-12-17

  • Last modified date

    2007-12-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: