Error description

  • GSD: MINIMUM DISTANCE IS INCORRECTLY
    MEASURED BY THE MEASURE BETWEEN COMMAND.
    .
    SCENARIO.
    1. Start CATIA V5R17SP03. Refer to the .ppt file
    attched.
    2. Open the file: SUR.CATPart. Workbench:
    Generative Shape Design.
    3. Select the Measure Between icon.  Measure
    Between window is displayed.
    4. Select SUR_1 and SUR_2 from specification
    tree.  Minimum distance of SUR_1 and SUR_2 is not
    measured correctly.
    Error: Minimum distance is not correctly measured
    by the Measure Between command.
    .
    .
    

Local fix

Problem summary

  • GSD: MINIMUM DISTANCE IS INCORRECTLY MEASURED BY THE MEASURE BE
    TWEEN COMMAND.
    GSD: MINIMUM DISTANCE IS INCORRECTLY
    MEASURED BY THE MEASURE BETWEEN COMMAND.
    .
    SCENARIO.
    1. Start CATIA V5R17SP03. Refer to the .ppt file
    attched.
    2. Open the file: SUR.CATPart. Workbench:
    Generative Shape Design.
    3. Select the Measure Between icon.  Measure
    Between window is displayed.
    4. Select SUR_1 and SUR_2 from specification
    tree.  Minimum distance of SUR_1 and SUR_2 is not
    measured correctly.
    Error: Minimum distance is not correctly measured
    by the Measure Between command.
    .
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP04.
    .
    Incident Diagnosis
    Ineffectiveness in choosing the Initial points (used
    for minimum distance calculation). Algorithm
    misses the face pair which achieves
    the minimum distance.
    .
    Correction Explanation.
    Some additional initial points are provided in
    addition to the current initial points. This ensures
    that the correct face pair is chosen for minimum
    distance calculation.
    .
    .
    

Temporary fix

Comments

  • 8 MMENTS:
    

APAR Information

  • APAR number

    HD69287

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-11-19

  • Closed date

    2008-01-22

  • Last modified date

    2008-03-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN SP51804

       UP08/03/26 I 1000

  • R517 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
26 March 2008