HD68609: SYNCHRONIZE TO ANY REVISION DOES NOT WORK ON AN ASSEMBLY DRAWI NG WHICH POINTS TO A PVR CATPRODUCT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • SYNCHRONIZE TO ANY REVISION  DOES NOT
    WORK ON AN ASSEMBLY DRAWING WHICH
    POINTS TO A PVR CATPRODUCT
    .
    SCENARIO:
    1) In order to activate PVR and PVS functionality
    the following environment
    variables are set in the Environment txt-file:
    ?VPMNav_CaptureContext=1?
    ?VPMV5_V5R17_PLUS=1?
    A] Preparation:
    .
    1) From Scratch build a simple assembly.
    No need to use a specific geometry in order to
    play the scenario.
    2) On the first assembly level underneath the PRC
    create a PVR.
    3) Based on the PVR create an assembly drawing.
    B]  Modify one of the detailed parts.
    .
    4) Close all open windows except the VPM-
    Navigator window.
    5) In VPM-Nav select the CATPart document of one
    of the two detailed
    parts and load it into CATIA 'out-of-context' into
    a single document
    window
    6) In CATIA modify the part.
    7) Save back the Part to ENOVIA (without creating
    new part version or
    document revision).
    8) Close the CATIA window.
    .
    C] Synchronize the PVR.
    .
    9) Open the PVR into CATIA.
    10) Synchronize the PVR to the exploded structure
    of the PRC
    11) Save the PVR back to ENOVIA (even if it tells,
    that it is up to date).
    by creating a new revision of the PVR.
    .
    D] Update the assembly drawing
    .
    12) Close all open CATIA windows except the VPM-
    Navigator.
    13) Open an impacted by Graph on the assembly
    drawing.
    =>it shows that a new revision of the PVR is
    available
    14) Open the Drawing into CATIA.
    15) Open the 'Edit / Links' Panel
    16) Switch to the pointed documents
    17) Select the button 'Replace with any revision' in
    order to synchronize
    the drawing to the new revision of the PVR.
    =>The All revisions window is displayed
    18) select the new revision of the PVR.
    19) Confirm with 'ok'.
    .
    ERROR - The following error messages are displayed
    Incident Report panel: with 2 lines
    Error Front - ... / Right view - ...
    One or several of Part instances referenced by the
    view cannot be found in the new Document.
    .
    

Local fix

Problem summary

  • SYNCHRONIZE TO ANY REVISION  DOES NOT WORK ON AN ASSEMBLY DRAWI
    NG WHICH POINTS TO A PVR CATPRODUCT
    SYNCHRONIZE TO ANY REVISION  DOES NOT
    WORK ON AN ASSEMBLY DRAWING WHICH
    POINTS TO A PVR CATPRODUCT
    .
    SCENARIO:
    1) In order to activate PVR and PVS functionality
    the following environment
    variables are set in the Environment txt-file:
    ?VPMNav_CaptureContext=1?
    ?VPMV5_V5R17_PLUS=1?
    A  Preparation:
    .
    1) From Scratch build a simple assembly.
    No need to use a specific geometry in order to
    play the scenario.
    2) On the first assembly level underneath the PRC
    create a PVR.
    3) Based on the PVR create an assembly drawing.
    B   Modify one of the detailed parts.
    .
    4) Close all open windows except the VPM-
    Navigator window.
    5) In VPM-Nav select the CATPart document of one
    of the two detailed
    parts and load it into CATIA 'out-of-context' into
    a single document
    window
    6) In CATIA modify the part.
    7) Save back the Part to ENOVIA (without creating
    new part version or
    document revision).
    8) Close the CATIA window.
    .
    C  Synchronize the PVR.
    .
    9) Open the PVR into CATIA.
    10) Synchronize the PVR to the exploded structure
    of the PRC
    11) Save the PVR back to ENOVIA (even if it tells,
    that it is up to date).
    by creating a new revision of the PVR.
    .
    D  Update the assembly drawing
    .
    12) Close all open CATIA windows except the VPM-
    Navigator.
    13) Open an impacted by Graph on the assembly
    drawing.
    =>it shows that a new revision of the PVR is
    available
    14) Open the Drawing into CATIA.
    15) Open the 'Edit / Links' Panel
    16) Switch to the pointed documents
    17) Select the button 'Replace with any revision' in
    order to synchronize
    the drawing to the new revision of the PVR.
    =>The All revisions window is displayed
    18) select the new revision of the PVR.
    19) Confirm with 'ok'.
    .
    ERROR - The following error messages are
    displayed
    Incident Report panel: with 2 lines
    Error Front - ... / Right view - ...
    One or several of Part instances referenced by the
    view cannot be found in the new Document.
    .
    Please see ?14393.025.724_071017080000_071016-
    ZF-PMR14393.doc? file for detail scenario at
    material path.
    .
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
    ENOVIA VERSION 5 RELEASE 17.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    ENOVIA VERSION 5 RELEASE 19 GA level AND ON
    V5R18SP02
    .
    

APAR Information

  • APAR number

    HD68609

  • Reported component name

    ENOVIA V5 VPM N

  • Reported component ID

    569151400

  • Reported release

    517

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-10-24

  • Closed date

    2007-10-26

  • Last modified date

    2007-11-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA V5 VPM N

  • Fixed component ID

    569151400

Applicable component levels

  • R518 PSN SP51802

       UP07/11/13 I 1000