HD67757: FILE INTROSPECTION: WHEN INTROSPECTION FORMATS ARE REGENERAED I N BATCH MODE ONE EXTRA FILE IS PROCESSED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FILE INTROSPECTION: WHEN INTROSPECTION
    FORMATS ARE REGENERAED IN BATCH MODE ONE
    EXTRA FILE IS PROCESSED
    .
    Pre-requisites:
    1] Create 6 CATParts in VPMNav and save to
    database
    2] The method of starting Introspection in Batch
    mode is checked at OnlineDocument.
    ENOVIA LCA - LifeCycle Administration Guide
    LCA Administration Guide - File Introspection
    - Batch Utility to Regenerate Derived Formats
    3] Refering to above documentation, an Input file
    containing list of document UUIDs of six CATParts
    created in step 1 is generated.
    .
    Scenario:
    1] Logon to a server by a LCA administrator user.
    2] Browse to following path.
    /[LCA_Install_Directory]/aix_a/code/command
    3] An environment is set up.
    4] Run the command
    ./catstart -run "FIRegenerateFormats.sh -Q
    FetchQuery -selection 5 -docPerPage 10 -
    PageNumber -1" -env ENOVIA_LCA.V5R16.B16 -
    direnv /usr/lca16/CATEnv
    5] Input file is specified. Since it is input file of
    UUID, 1 is the input
    6] The path of input file is specified.
    .
    Actual Result:
    7 files are processed althrough 6 UUIDs are
    specified.
    .
    Expected Result:
    When Introspection is performed in dialog mode,
    unnecessary cgr should not be processed.
    .
    

Local fix

Problem summary

  • FILE INTROSPECTION: WHEN INTROSPECTION FORMATS ARE REGENERAED I
    N BATCH MODE ONE EXTRA FILE IS PROCESSED
    FILE INTROSPECTION: WHEN INTROSPECTION
    FORMATS ARE REGENERAED IN BATCH MODE ONE
    EXTRA FILE IS PROCESSED
    .
    Pre-requisites:
    1  Create 6 CATParts in VPMNav and save to
    database
    2  The method of starting Introspection in Batch
    mode is checked at OnlineDocument.
    ENOVIA LCA - LifeCycle Administration Guide
    LCA Administration Guide - File Introspection
    - Batch Utility to Regenerate Derived Formats
    3  Refering to above documentation, an Input file
    containing list of document UUIDs of six CATParts
    created in step 1 is generated.
    .
    Scenario:
    1  Logon to a server by a LCA administrator user.
    2  Browse to following path.
    / LCA_Install_Directory /aix_a/code/command
    3  An environment is set up.
    4  Run the command
    ./catstart -run "FIRegenerateFormats.sh -Q
    FetchQuery -selection 5 -docPerPage 10 -
    PageNumber -1" -env ENOVIA_LCA.V5R16.B16 -
    direnv /usr/lca16/CATEnv
    5  Input file is specified. Since it is input file of
    UUID, 1 is the input
    6  The path of input file is specified.
    .
    Actual Result:
    7 files are processed althrough 6 UUIDs are
    specified.
    .
    Expected Result:
    When Introspection is performed in dialog mode,
    unnecessary cgr should not be processed.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON ENOVIA
    VERSION 5 RELEASE 19 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP03 AND ON V5R17SP08.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD67757

  • Reported component name

    ENOVIA LCA AIX

  • Reported component ID

    569101700

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-09-27

  • Closed date

    2007-11-02

  • Last modified date

    2008-01-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA LCA AIX

  • Fixed component ID

    569101700

Applicable component levels

  • R518 PSN SP51803

       UP08/01/25 I 1000

  • R517 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDJRN","label":"ENOVIA LCA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"","label":""}}]