APAR status
Closed as program error.
Error description
The CATIA V5 E&S Analyze/Design Validation Command returns an d error on the Validation Check Scenario: Send the PRC/GCO to CATIA V5 Create a WP with a Piping System Place some Straight Pipes with no Bends Execute in the Piping WB Analyze / Design Validation Command Select the WP The Validation Check: Bending Bend angle less than minimum allowed produces a report with an error on the Straight Pipe not applicable to this Rule. On the Violation Report you getting on your Straight Pipes on the Validation Check: Bending Bend angle less than minimum allowed DSA was able to reproduce the problem in the R17 Level. The problem exists with part type Pipe with bends when only ONE segment exists. For Part type Pipe the problem doesn t exist. DSA needs to update the Rule so when the Design Validation Tool is checking for bend angle criteria or any bend criteria, it needs to make sure that the pipe consists of more than one segment (more than 2 nodes) and make sure that there is a bend. .
Local fix
Problem summary
The CATIA V5 E and S Analyze/Design Validation Command returns an d error on the Validation Check The CATIA V5 E&S Analyze/Design Validation Command returns an d error on the Validation Check Scenario: Send the PRC/GCO to CATIA V5 Create a WP with a Piping System Place some Straight Pipes with no Bends Execute in the Piping WB Analyze / Design Validation Command Select the WP The Validation Check: Bending Bend angle less than minimum allowed produces a report with an error on the Straight Pipe not applicable to this Rule. On the Violation Report you getting on your Straight Pipes on the Validation Check: Bending Bend angle less than minimum allowed DSA was able to reproduce the problem in the R17 Level. The problem exists with part type Pipe with bends when only ONE segment exists. For Part type Pipe the problem doesn t exist. DSA needs to update the Rule so when the Design Validation Tool is checking for bend angle criteria or any bend criteria, it needs to make sure that the pipe consists of more than one segment (more than 2 nodes) and make sure that there is a bend. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 19 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R17SP07 AND THIS PROBLEM WILL ALSO BE FIXED ON V5R18SP02. .
Temporary fix
Comments
APAR Information
APAR number
HD67200
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-09-05
Closed date
2007-09-21
Last modified date
2007-10-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN SP51707
UP07/10/25 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
25 October 2007