  • Closed as program error.

Error description

  • PROBLEM:
    Run the Clean Command of CATDUA for the Part
    which has a imported feature (FeatureA) which link
    was broken.
    After that, get the imported feature of the CCP
    feature (it is a copy with link fiature of the
    FeatureA) which link was broaken.(
    CATIxPDMPartItem::GetImportedItems()) Then the
    method display a message.
    .
    SCENARIO:
    1. Open Sample data with our sampleWS.
    2. Activate Part2.
    3. Start ᆴ TESTCmdᆵ command, and  push OK
    button.
    4. The method
    CATIxPDMPartItem::GetImportedItems() was run
    for the     Part2 and it was normal   termination.
    5. Start Clean command of CATDUA for Part.1.
    (Part.1 was imported     feature of Part2)
    6. Do the step No2 , No3 again.
    .
    RESULT:
    In the method
    CATIxPDMPartItem::GetImportedItems() the
    message is   displayed as below:
    .
    Part1.CATPart is already open.
    Reopening will cause any changes you made to be
    discarded.
    Do you want to reopen it?
    .
    

Local fix

Problem summary

  • CATIxPDMPartItem::GetImportedItems() display Message
    PROBLEM:
    Run the Clean Command of CATDUA for the Part
    which has a imported feature (FeatureA) which link
    was broken.
    After that, get the imported feature of the CCP
    feature (it is a copy with link fiature of the
    FeatureA) which link was broaken.(
    CATIxPDMPartItem::GetImportedItems()) Then the
    method display a message.
    .
    SCENARIO:
    1. Open Sample data with our sampleWS.
    2. Activate Part2.
    3. Start   TESTCmd  command, and  push OK
    button.
    4. The method
    CATIxPDMPartItem::GetImportedItems() was run
    for the     Part2 and it was normal   termination.
    5. Start Clean command of CATDUA for Part.1.
    (Part.1 was imported     feature of Part2)
    6. Do the step No2 , No3 again.
    .
    RESULT:
    In the method
    CATIxPDMPartItem::GetImportedItems() the
    message is   displayed as below:
    .
    Part1.CATPart is already open.
    Reopening will cause any changes you made to be
    discarded.
    Do you want to reopen it?
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP02 V5R17SP07.
    .
    Incident Diagnosis:
    in PX1 code, use of FileMenu Open service leads to
    display a warning window !
    This is due to the fact , that the document to be
    open is already in session and is dirty.
    .
    Correction Explanation:
    Before the call of open service, we check if the
    document is present in session.
    .
    Answer and By-Pass:
    no by pass
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD66768

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-08-17

  • Closed date

    2007-09-18

  • Last modified date

    2007-11-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN SP51802

       UP07/11/13 I 1000

  • R517 PSN SP51707

       UP07/10/25 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
13 November 2007