  • Scenario :
    1- File / Open TEST_1.CATDrawing.
    Circles of Radius = 0.5mm are created on
    Sheet.1 and Front View.
    2- Select Edit / Search / General tab
    Specify "Workbench = Drafting", "Type = Circle"
    and perform search.
    The following 2 items are detected :
    Circle.1(Drawing / Sheet.1 / ViewMakeUP1 / Main
    View / Circle.1)
    Circle.1(Drawing / Sheet.1 / ViewMakeUP1 / Front
    View / Circle.1)
    3- Select
    Circle.1(Drawing / Sheet.1 / ViewMakeUP1 / Main
    View / Circle.1), right click and perform "Reframe
    On".
    Result :
    Display of screen does not change and reframe is
    not performed.
    .
    

Local fix

Problem summary

  • Apply "Reframe" to result of search
    Scenario :
    1- File / Open TEST_1.CATDrawing.
    Circles of Radius = 0.5mm are created on
    Sheet.1 and Front View.
    2- Select Edit / Search / General tab
    Specify "Workbench = Drafting", "Type = Circle"
    and perform search.
    The following 2 items are detected :
    Circle.1(Drawing / Sheet.1 / ViewMakeUP1 / Main
    View / Circle.1)
    Circle.1(Drawing / Sheet.1 / ViewMakeUP1 / Front
    View / Circle.1)
    3- Select
    Circle.1(Drawing / Sheet.1 / ViewMakeUP1 / Main
    View / Circle.1), right click and perform "Reframe
    On".
    Result :
    Display of screen does not change and reframe is
    not performed.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP01.
    Incident Diagnosis
    Cannot do a ReframeOn on main/background
    views.
    Correction Explanation
    The issue has been fixed
    Answer and By-Pass
    None
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD66035

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-07-16

  • Closed date

    2007-08-16

  • Last modified date

    2007-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN SP51801

       UP07/10/01 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]