  • STCAI : Error message when performing a check
    in on an assembly drawing, its children and their
    related drawings
    .
    CATIA Smarteam integration problem reproduced
    on Smdemo
    .
    Scenario :
    An assembly is composed of 2 parts. Each of these
    3 files has a drawing.
    1. Open the provided Assembly drawing and the 2
    Part drawings.
    2. Save in Smarteam the assembly drawing. Save
    in Smarteam the 2 part drawings.
    3. In the assembly drawing, do a smarteam/check
    in. In the 'check in window', use
    'Associated objects/CATIA links/All' in order to
    display the assembly, the 2 parts and
    their 2 drawings. Click the icons on the left (for the
    6 files) in order to check in the 6 files in one
    operation. Click OK.
    4. In smarteam editor, on the assembly drawing,
    do a 'open for edit'. Use 'Associated objects/CATIA
    links/All' in order to check out the 6 files in one
    operation. Click OK.
    5. The assembly drawing is now opened in CATIA.
    In Smarteam editor, do a 'open' on each of the 2
    part drawings. The 3 drawings are now opened in
    CATIA.
    6. Make a change to each of those 3 drawings.
    Check them in Smarteam in one operation (like in
    step 3).
    Problem : error message is displayed : 'Critical
    situation...documents are not in compliance with
    documents in the disk'
    .
    

Local fix

Problem summary

  • STCAI : Error message when performing a check in on an assembly
    drawing, its children and their related drawings
    STCAI : Error message when performing a check
    in on an assembly drawing, its children and their
    related drawings
    .
    CATIA Smarteam integration problem reproduced
    on Smdemo
    .
    Scenario :
    An assembly is composed of 2 parts. Each of these
    3 files has a drawing.
    1. Open the provided Assembly drawing and the 2
    Part drawings.
    2. Save in Smarteam the assembly drawing. Save
    in Smarteam the 2 part drawings.
    3. In the assembly drawing, do a smarteam/check
    in. In the 'check in window', use
    'Associated objects/CATIA links/All' in order to
    display the assembly, the 2 parts and
    their 2 drawings. Click the icons on the left (for the
    6 files) in order to check in the 6 files in one
    operation. Click OK.
    4. In smarteam editor, on the assembly drawing,
    do a 'open for edit'. Use 'Associated objects/CATIA
    links/All' in order to check out the 6 files in one
    operation. Click OK.
    5. The assembly drawing is now opened in CATIA.
    In Smarteam editor, do a 'open' on each of the 2
    part drawings. The 3 drawings are now opened in
    CATIA.
    6. Make a change to each of those 3 drawings.
    Check them in Smarteam in one operation (like in
    step 3).
    Problem : error message is displayed : 'Critical
    situation...documents are not in compliance with
    documents in the disk'
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP02 AND ON V5R17SP07.
    Incident Diagnosis
    Part drawings were skipped for saving since they
    are not in the direct hierarchy of the Assembly
    drawing
    Correction Explanation
    The issue has been fixed. Those Part drawings are
    now saved.
    However, the Save time during CheckIn is
    increased since these extra saves are added.
    Note : It's still better to Save the part drawings
    explicitely before
    CheckIn the assembly if we want to Check In them
    along with
    the assembly drawing.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD65628

  • Reported component name

    SMARTEAM NT>XP

  • Reported component ID

    569199970

  • Reported release

    517

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-07-03

  • Closed date

    2007-09-07

  • Last modified date

    2007-10-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SMARTEAM NT>XP

  • Fixed component ID

    569199970

Applicable component levels

  • R517 PSN SP51707

       UP07/10/25 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
25 October 2007