APAR status
Closed as unreproducible in next release.
Error description
SAVE FAILS FOR A CATPART STORED BY DBLFLCA AND LOADED VIA 3DCOM. SAVE FAILS FOR A CATPART STORED BY DBLFLCA AND LOADED VIA 3DCOM. SCENARIO: 1) Logon to 3d com and start the VPM Web Access. 2) Select a CATPart stored with DBLFLCA in a 3d com workbook. 3) Select CATIA_V5 / Load from the context menu. 4) In CATIA V5 the CATPart is displayed. Modify the diameter of a hole. 5) Select File / Save in CATIA V5. RESULT: There are two error message displayed in CV5. 1. Error Message : Save in the PDM The save was not successful Short Message : DATABASE ERROR 165 THE DBLFLCA ACCESS METHOD RETURNED AN INVALID DIAGNOSIS ******** FOR AN OPERATION GEN NEW DATA . DATABASE COMMAND : Long Message : DATABASE ERROR 2. Error Message : Save document in the ENOVIAvpm The update was not successful ENOVIAvpm return code : 110 Short Message : DATABASE ERROR Long Message : DATABASE ERROR 165 THE DBLFLCA ACCESS METHOD RETURNED AN INVALID DIAGNOSIS .
Local fix
Problem summary
SAVE FAILS FOR A CATPART STORED BY DBLFLCA AND LOADED VIA 3DCOM . SAVE FAILS FOR A CATPART STORED BY DBLFLCA AND LOADED VIA 3DCOM. SAVE FAILS FOR A CATPART STORED BY DBLFLCA AND LOADED VIA 3DCOM. SCENARIO: 1) Logon to 3d com and start the VPM Web Access. 2) Select a CATPart stored with DBLFLCA in a 3d com workbook. 3) Select CATIA_V5 / Load from the context menu. 4) In CATIA V5 the CATPart is displayed. Modify the diameter of a hole. 5) Select File / Save in CATIA V5. RESULT: There are two error message displayed in CV5. 1. Error Message : Save in the PDM The save was not successful Short Message : DATABASE ERROR 165 THE DBLFLCA ACCESS METHOD RETURNED AN INVALID DIAGNOSIS ******** FOR AN OPERATION GEN NEW DATA . DATABASE COMMAND : Long Message : DATABASE ERROR 2. Error Message : Save document in the ENOVIAvpm The update was not successful ENOVIAvpm return code : 110 Short Message : DATABASE ERROR Long Message : DATABASE ERROR 165 THE DBLFLCA ACCESS METHOD RETURNED AN INVALID DIAGNOSIS .
Problem conclusion
Temporary fix
Comments
null ==========*===========*========== THE PROBLEM WAS SUBMITTED ON : ENOVIA VPM1.5PTF29 THIS PROBLEM IS NOT REPRODUCIBLE ON : ENOVIA VPM1.6PTF05 AND ON ENOVIA VPM1.5PTF39 Incident Diagnosis: SAVE FAILS FOR A CATPART STORED BY DBLFLCA AND LOADED VIA 3DCOM. Correction Explanation: Already corrected .
APAR Information
APAR number
HD65070
Reported component name
ENOVIA VPM AIX
Reported component ID
569101900
Reported release
150
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-06-20
Closed date
2007-06-29
Last modified date
2007-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ENOVIA VPM AIX
Fixed component ID
569101900
Applicable component levels
R150 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSEPMN","label":"ENOVIAvpm"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"150","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
24 September 2007