APAR status
Closed as Permanent restriction.
Error description
Reproducibility Reproducibility is different according to the setting of "Linked Document Localization" It reproduces it when "Folder of pointing doucument" is top priority. (See ppt) . Scenario 1. Open "AAA.CATProduct". 2. "Desk" of CATIA is executed. Load is executed for BBB and CCC. 3. Select "File/Savemanagement" and save all documents to "C:\tmp\Samlpe". 4. Close "AAA.CATPart". 5. Open "C:\tmp\Samlpe\AAA.CATPart". 6. PMR_SaveAs2.CATScript is executed. The macro save AAA.CATPart in a "C:\tmp\Sample" Folder. It is necessay to change "Folder of pointing doucument" (PMR 73518) 7. The macro save BBB.CATPart in a "C:\tmp\AnotherFolder" Folder. At this time, the state of of CATPart is changed WM_VISUALIZATION to WM_DESIGN. 8. The macro liberates the memory by changing the state of CATPart to WM_VISUALIZATION. 9. CATProduct is linked with the file before it preserves it according to the option setting. 10. The macro save CCC.CATPart in a "C:\tmp\Sample" path. 11. The macro save AAA.CATProduct in a "C:\tmp\Sample" path again. (It is necessary to update child path.) This message is displayed, processing finihed. 12. Close AAA.CATProduct. 13. Delete "c:\tmp\BBB.CATPart", because it is saved in a new folder. 14. Open AAA.CATProduct AAA.CATProduct has broken link. "C:\tmp\AnotherFolder" is not found. If nearest document is not found, relative folder is checked from "Linked Document Localization" However, relative folder is not checked in R17. .
Local fix
Problem summary
The file path of a CATPart saved using CATDocumentServices::SaveAs in a relative folder is not kept Reproducibility Reproducibility is different according to the setting of "Linked Document Localization" It reproduces it when "Folder of pointing doucument" is top priority. (See ppt) . Scenario 1. Open "AAA.CATProduct". 2. "Desk" of CATIA is executed. Load is executed for BBB and CCC. 3. Select "File/Savemanagement" and save all documents to "C:\tmp\Samlpe". 4. Close "AAA.CATPart". 5. Open "C:\tmp\Samlpe\AAA.CATPart". 6. PMR_SaveAs2.CATScript is executed. The macro save AAA.CATPart in a "C:\tmp\Sample" Folder. It is necessay to change "Folder of pointing doucument" (PMR 73518) 7. The macro save BBB.CATPart in a "C:\tmp\AnotherFolder" Folder. At this time, the state of of CATPart is changed WM_VISUALIZATION to WM_DESIGN. 8. The macro liberates the memory by changing the state of CATPart to WM_VISUALIZATION. 9. CATProduct is linked with the file before it preserves it according to the option setting. 10. The macro save CCC.CATPart in a "C:\tmp\Sample" path. 11. The macro save AAA.CATProduct in a "C:\tmp\Sample" path again. (It is necessary to update child path.) This message is displayed, processing finihed. 12. Close AAA.CATProduct. 13. Delete "c:\tmp\BBB.CATPart", because it is saved in a new folder. 14. Open AAA.CATProduct AAA.CATProduct has broken link. "C:\tmp\AnotherFolder" is not found. If nearest document is not found, relative folder is checked from "Linked Document Localization" However, relative folder is not checked in R17. .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA. Note: bypass has been provided to customer. .
Temporary fix
Comments
APAR Information
APAR number
HD64907
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-06-06
Closed date
2007-06-29
Last modified date
2007-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
29 June 2007