APAR status
Closed as Permanent restriction.
Error description
PART: INSTANTIATE FROM DOCUMENT: WARNING MESSAGE IS DISPLAYED EVEN THOUGH THE INSERTION POSITION IS DECIDED . SCENARIO: 0) Start CATIA 1) Open NUL-269.CATPart. 2) Select Insert - Instantiate From Document. 3) Open NUL-269-P.CATPart. = Warning Message is displayed. 4) Click Use identical name in Insert Object window, = even if either Inside or After is selected as Destination, the feature is inserted in the same position on a tree. . OBSERVATION: Warning message is displayed even if Destination is already decided. .
Local fix
Problem summary
PART: INSTANTIATE FROM DOCUMENT: WARNING MESSAGE IS DISPLAYED E VEN THOUGH THE INSERTION POSITION IS DECIDED PART: INSTANTIATE FROM DOCUMENT: WARNING MESSAGE IS DISPLAYED EVEN THOUGH THE INSERTION POSITION IS DECIDED . SCENARIO: 0) Start CATIA 1) Open NUL-269.CATPart. 2) Select Insert - Instantiate From Document. 3) Open NUL-269-P.CATPart. = Warning Message is displayed. 4) Click Use identical name in Insert Object window, = even if either Inside or After is selected as Destination, the feature is inserted in the same position on a tree. . OBSERVATION: Warning message is displayed even if Destination is already decided. .
Problem conclusion
null ==========*===========*========== THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA . Incident Diagnosis: A Warning message is displayed when instantiating a Power Copy containing a Boolean Operation and its Operated Body. . Restriction Explanation: When instantiating the Power Copy, the destination where the components of the Power Copy will be inserted, is the current feature: the Part Body. All the components of the Power Copy are asked if they are authorized to be inserted at this location. Since you are not working in a Hybrid Body environment, the Boolean Operation does not aggregate the Operated Body and thus, there are 2 components in the Power Copy: the Boolean Operation and its Operated Body. The Bolean Operation can be inserted without any problem inside the Part Body, but the operated body cannot be inserted indide the Part Body, that is why a warning message is displayed: it is explaining that the Body will be inserted at another location which is not the current feature. This is a R17 development. And the Operated Body is effectively inserted inside the Boolean Operation and not directly inside the Part Body. If you change the relative position to After, then a warning message is displayed, because this time, the Boolean Operation cannot be inserted after the Part Body, but the Operated Body can be inserted after the Part Body. Thus the instantiation is authorized but a warning message is displayed. Note that it is not the same as the one displayed with the Inside position. This time the message refers to the Boolean Operation. . No bypass: It is just a warning message, and it does not prevent the correct instantiation of the Power Copy. Please refer to Part Design Workbench documentation to know more about the Hybrid Body environment. .
Temporary fix
Comments
APAR Information
APAR number
HD64901
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-06-06
Closed date
2007-06-07
Last modified date
2007-06-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
07 June 2007