APAR status
Closed as program error.
Error description
NC REVIEW / MACHINING PROCESS INSTANTIATION FAILS . Scenario . 1. install the supplied catalog file in the intel_a\startup\Manufacturing\Tools library 2. Open the Counterdrilled.CATProcess in Catia PMG 3. Open the Manufacturing View, sort by machining features and find the counterdrilled hole 4. Select the Machining Processes Instantiation 5. Select the counterdrilled hole as feature Select the ExpansionHoles.catalog as catalog, and select the EXP10 from the Machining Processes List as process to instatiate 6. Select OK. - warning Check execution has failed. 7. Now there is a warning popping up on the screen. That the Counterbore diameter cannot be used. 8. Select OK to the warning 9. Doubleclick on the Machineable Axial Feature.1 in the manufacturing View 10. Observe that there is a parameter called Counterbore diameter. 11. Now open the Expansionholes.CATProcess 12. Open the machining Process View 13. Rightclick on the EXP10 in the tree, and select edit Checks. 14. There is a check on the Counterbore diameter but this is not working .
Local fix
Problem summary
NC REVIEW / MACHINING PROCESS INSTANTIATION FAILS NC REVIEW / MACHINING PROCESS INSTANTIATION FAILS . Scenario . 1. install the supplied catalog file in the intel_a\startup\Manufacturing\Tools library 2. Open the Counterdrilled.CATProcess in Catia PMG 3. Open the Manufacturing View, sort by machining features and find the counterdrilled hole 4. Select the Machining Processes Instantiation 5. Select the counterdrilled hole as feature Select the ExpansionHoles.catalog as catalog, and select the EXP10 from the Machining Processes List as process to instatiate 6. Select OK. - warning Check execution has failed. 7. Now there is a warning popping up on the screen. That the Counterbore diameter cannot be used. 8. Select OK to the warning 9. Doubleclick on the Machineable Axial Feature.1 in the manufacturing View 10. Observe that there is a parameter called Counterbore diameter. 11. Now open the Expansionholes.CATProcess 12. Open the machining Process View 13. Rightclick on the EXP10 in the tree, and select edit Checks. 14. There is a check on the Counterbore diameter but this is not working .
Problem conclusion
null ==========*===========*========== THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 18 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R17SP06. . Now,the parameters for CounterDrill is exposed to the user on R17 level onwards too. .
Temporary fix
Comments
APAR Information
APAR number
HD63513
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-04-18
Closed date
2007-05-31
Last modified date
2007-06-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R517 PSN SP51706
UP07/06/28 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
28 June 2007