IBM Support

HD63513: NC REVIEW / MACHINING PROCESS INSTANTIATION FAILS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • NC REVIEW / MACHINING PROCESS
    INSTANTIATION FAILS
    .
    Scenario
    .
    1. install the supplied catalog file in the
    intel_a\startup\Manufacturing\Tools library
    2. Open the Counterdrilled.CATProcess in Catia
    PMG
    3. Open the Manufacturing View, sort by machining
    features and find the
    counterdrilled hole
    4. Select the Machining Processes Instantiation
    5. Select the counterdrilled hole as feature Select
    the
    ExpansionHoles.catalog as catalog, and select the
    EXP10 from the
    Machining Processes List as process to instatiate
    6. Select OK.
    - warning Check execution has failed.
    7. Now there is a warning popping up on the
    screen. That the
    Counterbore diameter cannot be used.
    8. Select OK to the warning
    9. Doubleclick on the Machineable Axial Feature.1
    in the manufacturing
    View
    10. Observe that there is a parameter called
    Counterbore diameter.
    11. Now open the Expansionholes.CATProcess
    12. Open the machining Process View
    13. Rightclick on the EXP10 in the tree, and select
    edit Checks.
    14. There is a check on the Counterbore diameter
    but this is not working
    .
    

Local fix

Problem summary

  • NC REVIEW / MACHINING PROCESS INSTANTIATION FAILS
    NC REVIEW / MACHINING PROCESS
    INSTANTIATION FAILS
    .
    Scenario
    .
    1. install the supplied catalog file in the
    intel_a\startup\Manufacturing\Tools library
    2. Open the Counterdrilled.CATProcess in Catia
    PMG
    3. Open the Manufacturing View, sort by machining
    features and find the
    counterdrilled hole
    4. Select the Machining Processes Instantiation
    5. Select the counterdrilled hole as feature Select
    the
    ExpansionHoles.catalog as catalog, and select the
    EXP10 from the
    Machining Processes List as process to instatiate
    6. Select OK.
    - warning Check execution has failed.
    7. Now there is a warning popping up on the
    screen. That the
    Counterbore diameter cannot be used.
    8. Select OK to the warning
    9. Doubleclick on the Machineable Axial Feature.1
    in the manufacturing
    View
    10. Observe that there is a parameter called
    Counterbore diameter.
    11. Now open the Expansionholes.CATProcess
    12. Open the machining Process View
    13. Rightclick on the EXP10 in the tree, and select
    edit Checks.
    14. There is a check on the Counterbore diameter
    but this is not working
    .
    

Problem conclusion

  • null
    ==========*===========*==========
    THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R17SP06.
    .
    Now,the parameters for CounterDrill is
    exposed to the user on R17 level onwards too.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD63513

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-04-18

  • Closed date

    2007-05-31

  • Last modified date

    2007-06-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R517 PSN SP51706

       UP07/06/28 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
28 June 2007