APAR status
Closed as suggestion for future release.
Error description
PS: LOADING OF DESIGN MODE AND VISUALIZATION MODE IS DIFFERENT. . SETTINGS: 1) Select "Tools" > "Options" by menu bar. "Option" dialog box is displayed. 2) Select "Assembly Design" on the tree. 3) Select "General" tab. 4) Select "Automatic" as "Compute exact update status at open". 5) Select "General" on the tree. 6) Select "Document" tab. 7) Rearrange "Linked Document Localization" as Following. "Folder of the pointing document" "Relative folder" "Folder of link" 8) Click "OK". 9) Restart CATIA. . SCENARIO: 0) Start CATIA. Check form of "Part3.CATPart: 1) Open the file: "Part3.CATPart". Workbench: "GSD". (Please confirm that the surface is a cylinder.) 2) Open the file: "Part3.CATPart" in "BBB" folder. Workbench: "GSD". (Please confirm that the surface is a square.) 3) Close those files. In the case of "Design mode: 4) Open the file: "T9466.CATProduct" in "BBB" folder. Workbench: "Assembly Design". (Please confirm that the surface of square is displayed.) 5) Select "File" > "Save Management" by menu bar. "Save Management" dialog box is displayed. 6) Click "Save As". "Save As" dialog box is displayed. 7) Click "Moves to the upper folder". Folder is changed to upper. 8) Click "Save". "Save Management" dialog box is displayed. 9) Click "OK". (Save the only "CATProduct" to upper folder.) 10) Close this file. 11) Open the "CATProduct" file saved at Step 9. "Open" dialog box is displayed. "Part3" is not loaded. 12) Click "Close". 13) Close this file. Change the option: 14) Delete the "CATProduct" file saved at Step 9. 15) Select "Tools" > "Options" by menu bar. "Option" dialog box is displayed. 16) Select "Product Structure" on the tree. 17) Select "Cache Management" tab. 18) Activate "Work with cache system". 19) Click "OK". 20) Restart CATIA. In the case of "Visualization mode: 21) Open the file: "T9466.CATProduct" in "BBB" folder. Workbench: "Assembly Design". (Please confirm that the surface of square is displayed by CGR.) 22) Select "File" > "Save Management" by menu bar. "Save Management" dialog box is displayed. 23) Click "Save As". "Save As" dialog box is displayed. 24) Click "Moves to the upper folder". Folder is changed to upper. 25) Click "Save". "Save Management" dialog box is displayed. 26) Click "OK". (Save the only "CATProduct" to upper folder.) 27) Close this file. 28) Open the "CATProduct" file saved at Step 26. "Open" dialog box is displayed. The surface of cylinder is displayed by CGR. This is problem. (CGR of "Par3" which exists in the same folder as "Product1" is displayed.) 29) Click "Part3.1(Part3.CATPart)" on the tree by MB3. 30) Select "Representations" > "Design Mode" by context menu. Display is not changed to design mode. This is problem. . .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
null ==========*===========*========== THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT WHICH CANNOT BE INCORPORATED IN VERSION V5R18 PLEASE CONTACT YOUR SUPPORT DEPARTMENT IN ORDER TO OPEN A REQUIREMENT FORM. . Incident Diagnosis: PS: LOADING OF DESIGN MODE AND VISUALIZATION MODE IS DIFFERENT. . Development Request Justification: New setting needs to be developed. . Concerning this issue, specific to the Visualization Mode, here is the explanation 1. First, the 2 CATParts has the same name but not the same UUID (internal identifier). 2. The Visualisation & Cache process is based on DocId. Here, we are able the retrieve a correct DocId for the CATPart (in the father of BBB directory), but we are not able to check whether this DocId contains the reference object of the instance. To do so, we need to open the document and solve the Instance-Reference link (that is to see if UUID match between Instance and Reference). And we cannot do such operation because it can lead to huge regression (one would need to open all the CATPart in this case,which is not acceptable). . There is a possiblity to develop a new setting that allows user to perform this check, but this will be a new development which cannot be done in actual releases as it requires a full new functionnal development. We invite you to follow Enhancement Request process to participate to this development definition. . .
APAR Information
APAR number
HD63414
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-04-16
Closed date
2007-06-08
Last modified date
2007-06-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
08 June 2007