  • GSMD : SURFACE STAMP : SURFACE STAMP CAN
    NOT BE CREATED IN A SPECIFIC CATPART
    .
    SCENARIO:
    1. Open Sample1.CATPart in GSMD workbench
    2. Click Surface Stamp icon. Surface Stamp
    definition dialog box appears.
    3. Select Folded curve.1 as Profile
    4. Click OK to Surface Stamp definition dialog box.
    .
    OBSERVATION1:
    Surface stamp is created successfully.
    .
    6. Double click on Surface Stamp.1 in specification
    tree. Surface Stamp definition dialog box appears.
    7. Change the stamp direction in 3D geometry area.
    .
    OBSERVATION2:
    An unexpected error occurred during the build.
    Surafce stamp cannot be created
    .
    

Local fix

Problem summary

  • GSMD : SURFACE STAMP : SURFACE STAMP CAN NOT BE CREATED IN A SP
    ECIFIC CATPART
    GSMD : SURFACE STAMP : SURFACE STAMP CAN
    NOT BE CREATED IN A SPECIFIC CATPART
    .
    SCENARIO:
    1. Open Sample1.CATPart in GSMD workbench
    2. Click Surface Stamp icon. Surface Stamp
    definition dialog box appears.
    3. Select Folded curve.1 as Profile
    4. Click OK to Surface Stamp definition dialog box.
    .
    OBSERVATION1:
    Surface stamp is created successfully.
    .
    6. Double click on Surface Stamp.1 in specification
    tree. Surface Stamp definition dialog box appears.
    7. Change the stamp direction in 3D geometry area.
    .
    OBSERVATION2:
    An unexpected error occurred during the build.
    Surafce stamp cannot be created
    .
    

Problem conclusion

  • null
    ==========*===========*==========
    THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R17SP06
    .
    Incident Diagnosis
    surface stamp is not created correctly
    .
    Correction Explanation
    The stamp profile FoldedCurve1 was not correctly
    projected on the impacted surface of the 3D
    geometry. Problem now fixed.
    .
    Answer and By-Pass
    None
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD63352

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-04-12

  • Closed date

    2007-05-15

  • Last modified date

    2007-06-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R517 PSN SP51706

       UP07/06/28 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
28 June 2007