IBM Support

HD62178: PART : MEASRUE : RESULT OF MEASURE BETWEEN 2 SURFACES BY FORMUL A BECOME UNSET

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PART : MEASRUE : RESULT OF MEASURE BETWEEN
    2 SURFACES BY FORMULA BECOME UNSET
    .
    SCENARIO:
    1. Open Supplied CATPart.
    2. Select "Measure Between" icon. Measure
    Between dialog box appears
    3. Select Surface "a" and then surface ᄄSurface.2ᄄ
    from specification tree
    .
    OBSERVATION1:
    Length measured is "1.056 mm"
    .
    4. Select "Formula" icon. Formulas dialog box
    appears.
    5. Select new parameter type as length and click
    on create new parameter button. Length.1
    parameter is created.
    6. Select Length.1 and click "Add Formula" button.
    Formula editor dialog box appears.
    7. Select Measures from dictionary field.
    8. Select Distance (Body, Body): Length option
    from members of measure field.
    9. Select Surface "a" and then surface ᄄSurface.2ᄄ
    from specification tree.
    10. Click OK to Formula editor dialog box.
    Automatic update warning message is displayed.
    11. Click YES to Automatic update warning
    message.
    .
    OBSERVATION2:
    Evaluation error in formula message is displayed.
    On clicking OK to this error message the measure
    result is set to unset.
    .
    

Local fix

Problem summary

  • PART : MEASRUE : RESULT OF MEASURE BETWEEN 2 SURFACES BY FORMUL
    A BECOME UNSET
    PART : MEASRUE : RESULT OF MEASURE BETWEEN
    2 SURFACES BY FORMULA BECOME UNSET
    .
    SCENARIO:
    1. Open Supplied CATPart.
    2. Select "Measure Between" icon. Measure
    Between dialog box appears
    3. Select Surface "a" and then surface  Surface.2
    from specification tree
    .
    OBSERVATION1:
    Length measured is "1.056 mm"
    .
    4. Select "Formula" icon. Formulas dialog box
    appears.
    5. Select new parameter type as length and click
    on create new parameter button. Length.1
    parameter is created.
    6. Select Length.1 and click "Add Formula" button.
    Formula editor dialog box appears.
    7. Select Measures from dictionary field.
    8. Select Distance (Body, Body): Length option
    from members of measure field.
    9. Select Surface "a" and then surface  Surface.2
    from specification tree.
    10. Click OK to Formula editor dialog box.
    Automatic update warning message is displayed.
    11. Click YES to Automatic update warning
    message.
    .
    OBSERVATION2:
    Evaluation error in formula message is displayed.
    On clicking OK to this error message the measure
    result is set to unset.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R17SP06
    .
    Incident Diagnosis
    Measure formula gives wrong result
    .
    Correction Explanation
    Correction done
    .
    Answer and By-Pass
    None
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD62178

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-02-28

  • Closed date

    2007-05-03

  • Last modified date

    2007-06-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R516 PSN

       UP

  • R517 PSN SP51706

       UP07/06/28 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
28 June 2007