Error description

  • PART: MULTISECTION SOLID - UPDATE ERROR
    OCCURS DURING MULTI SECTIONS SOLID
    OPERATION.
    .
    SCENARIO:
    1. Open the sample.CATPart.
    2. Click Multi-sections Solid icon.
    3. Select Sketch.2, Sketch.3 and Sketch.4
    4. Enable Deviation and input 0.005 mm.
    5. Click OK button. Update Error occurs. Multi-
    sections Solid.1 Invalid, empty or missing input
    element One mandatory input element is invalid,
    empty or missing There is no solution for this
    operation.
    This is the problem.
    .
    .
    

Local fix

Problem summary

  • PART: MULTISECTION SOLID - UPDATE ERROR OCCURS DURING MULTI SEC
    TIONS SOLID OPERATION.
    PART: MULTISECTION SOLID - UPDATE ERROR
    OCCURS DURING MULTI SECTIONS SOLID
    OPERATION.
    .
    SCENARIO:
    1. Open the sample.CATPart.
    2. Click Multi-sections Solid icon.
    3. Select Sketch.2, Sketch.3 and Sketch.4
    4. Enable Deviation and input 0.005 mm.
    5. Click OK button. Update Error occurs. Multi-
    sections Solid.1 Invalid, empty or missing input
    element One mandatory input element is invalid,
    empty or missing There is no solution for this
    operation.
    This is the problem.
    .
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R17SP05.
    .
    ADDITIONAL INFORMATION:
    The multi-section solid can be created correctly at
    0.005mm deviation also.
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD61627

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-02-12

  • Closed date

    2007-03-14

  • Last modified date

    2007-05-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R517 PSN SP51705

       UP07/05/04 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: