IBM Support

HD61322: FSS: BREAK SURFACE: NO OPTION TO SELECT THE SIDE TO KEEP FOR PA RTICULAR CATPART

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FSS: BREAK SURFACE: NO OPTION TO SELECT
    THE SIDE TO KEEP FOR PARTICULAR CATPART
    .
    SCENARIO:
    1) Start CATIA.
    2) Open CR141632.CATPart
    3) Start the FreeStyle Workbench (under Shape)
    4) Select the "Break Curve or Surface" tool
    (Operations toolbar.)
    5) On the Break dialogue box, use the following
    settings:
    Break Type: Surface
    Elements: Surface 1
    Limitation: Isoparameter 1
    Trim Type: Surface
    Order: Keep Order is active.
    6) Select Apply.
    .
    OBSERVATION:
    The result is the surface is broken, but the user
    does not have the capability to choose which side
    of the surface is kept and which side is removed.
    .
    

Local fix

Problem summary

  • FSS: BREAK SURFACE: NO OPTION TO SELECT THE SIDE TO KEEP FOR PA
    RTICULAR CATPART
    FSS: BREAK SURFACE: NO OPTION TO SELECT
    THE SIDE TO KEEP FOR PARTICULAR CATPART
    .
    SCENARIO:
    1) Start CATIA.
    2) Open CR141632.CATPart
    3) Start the FreeStyle Workbench (under Shape)
    4) Select the "Break Curve or Surface" tool
    (Operations toolbar.)
    5) On the Break dialogue box, use the following
    settings:
    Break Type: Surface
    Elements: Surface 1
    Limitation: Isoparameter 1
    Trim Type: Surface
    Order: Keep Order is active.
    6) Select Apply.
    .
    OBSERVATION:
    The result is the surface is broken, but the user
    does not have the capability to choose which side
    of the surface is kept and which side is removed.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R17SP05.
    .
    Incident Diagnosis:
    New algorithm for the selection of the relimited
    surface was not giving correct results for the
    particular part.
    .
    Correction Explanation:
    Algorithm modified to get correct results.
    Now we get the option to select the part to be kept.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD61322

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-01-31

  • Closed date

    2007-03-14

  • Last modified date

    2007-05-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: