IBM Support

HD60483: ASD: ELEMENTS OF EXTERNAL REFERENCE ARE NOT CHANGED TO ACTIVATI ON IN VISU MODE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ASD: ELEMENTS OF EXTERNAL REFERENCE ARE
    NOT CHANGED TO ACTIVATION IN VISU MODE.
    .
    SETTINGS:
    1) Select "Tools" > "Options" by menu
    bar. "Option" dialog box is displayed.
    2) Select "Product Structure" on the tree.
    3) Select "Cache Management" tab.
    4) Activate the "Work with the cache system".
    5) Click "OK".
    6) Restart CATIA.
    .
    SCENARIO:
    0) Start CATIA.
    1) Open the file: "T9270.CATProduct".
    Workbench: "Assembly Design".
    2) Click "Part2.1(Part2.CATPart)" on the tree by
    MB3.
    3) Select "Representations" > "Design Mode" by
    context menu. "Part2" is changed to design mode.
    4) Expand "Part2(Part2.1)" on the tree. "Part2" is
    displayed on the tree.
    5) Expand "Part2" on the tree. "External
    References" is displayed on the tree.
    6) Expand "External References" on the tree.
    (Please confirm that "Lin.1" and "Sketch.1" are
    deactivation.)
    7) Click "Part1.1(Part1.CATPart)" on the tree by
    MB3.
    8) Select "Part1.1 object" > "Activate / Deactivate
    Component" by context menu. "Part1.1
    (Part1.CATPart)" is changed to activation. "Lin.1"
    and "Sketch.1" of "External References" are not
    changed to activation.
    9) Click "Part1.1(Part1.CATPart)" on the tree by
    MB3.
    10) Select "Representations" > "Design Mode" by
    context menu. "Lin.1" and "Sketch.1" of "External
    References" are not changed to activation. This is
    problem.
    .
    .
    

Local fix

Problem summary

  • ASD: ELEMENTS OF EXTERNAL REFERENCE ARE NOT CHANGED TO ACTIVATI
    ON IN VISU MODE.
    ASD: ELEMENTS OF EXTERNAL REFERENCE ARE
    NOT CHANGED TO ACTIVATION IN VISU MODE.
    .
    SETTINGS:
    1) Select "Tools" > "Options" by menu
    bar. "Option" dialog box is displayed.
    2) Select "Product Structure" on the tree.
    3) Select "Cache Management" tab.
    4) Activate the "Work with the cache system".
    5) Click "OK".
    6) Restart CATIA.
    .
    SCENARIO:
    0) Start CATIA.
    1) Open the file: "T9270.CATProduct".
    Workbench: "Assembly Design".
    2) Click "Part2.1(Part2.CATPart)" on the tree by
    MB3.
    3) Select "Representations" > "Design Mode" by
    context menu. "Part2" is changed to design mode.
    4) Expand "Part2(Part2.1)" on the tree. "Part2" is
    displayed on the tree.
    5) Expand "Part2" on the tree. "External
    References" is displayed on the tree.
    6) Expand "External References" on the tree.
    (Please confirm that "Lin.1" and "Sketch.1" are
    deactivation.)
    7) Click "Part1.1(Part1.CATPart)" on the tree by
    MB3.
    8) Select "Part1.1 object" > "Activate / Deactivate
    Component" by context menu. "Part1.1
    (Part1.CATPart)" is changed to activation. "Lin.1"
    and "Sketch.1" of "External References" are not
    changed to activation.
    9) Click "Part1.1(Part1.CATPart)" on the tree by
    MB3.
    10) Select "Representations" > "Design Mode" by
    context menu. "Lin.1" and "Sketch.1" of "External
    References" are not changed to activation. This is
    problem.
    .
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R17SP05.
    .
    Incident Diagnosis:
    The External References are not activated /
    deactivated in case of a pointed instance
    is activated / desactivated and is in Visu Mode.
    .
    Correction Explanation:
    The links on Publication are not resolved in this
    case. This is now corrected and result is as
    expected.
    .                                 517
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD60483

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-01-03

  • Closed date

    2007-03-26

  • Last modified date

    2007-05-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R517 PSN SP51705

       UP07/05/04 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: