APAR status
Closed as unreproducible in next release.
Error description
PDG : MEASURE BETWEEN : THE ORIENTATION OF THE ANGLE QUADERANT IS CHANGED AFTER MODIFYING THE PARAMETER . SCENARIO: 1. Start CATIA and click on Tools menu and select options command. Options dialog box appears. 2. Go to Parameters and Measure ᄄ Knowledge tab page. 3. Check ON the option with value and with formula. 4. Go to Parameters and Measure ᄄ Measure tool tab page. 5. Check ON option Automatic Update in Part and Automatic Update in product option. 6. Go to infrastructure ᄄ Part infrastructure ᄄ display tab page. 7. Check ON option Parameters, Constraints and Relations. 8. Click OK to options dialog box. 9. Open TEST_SAMPLE_061121.CATPart. . OBSERVATION1: The angle value is 5.001 degrees.. . 10. Expand Parameter node in specification tree. 11. Double click on ᄄSet_Param_01ᄄ. Edit parameter dialog box appears. 12. Change the value to 500. 13. Click OK to Edit parameter dialog box. . OBSERVATION2: The angle value is changed to 354.999 degrees .
Local fix
Problem summary
PDG : MEASURE BETWEEN : THE ORIENTATION OF THE ANGLE QUADERANT IS CHANGED AFTER MODIFYING THE PARAMETER PDG : MEASURE BETWEEN : THE ORIENTATION OF THE ANGLE QUADERANT IS CHANGED AFTER MODIFYING THE PARAMETER . SCENARIO: 1. Start CATIA and click on Tools menu and select options command. Options dialog box appears. 2. Go to Parameters and Measure Knowledge tab page. 3. Check ON the option with value and with formula. 4. Go to Parameters and Measure Measure tool tab page. 5. Check ON option Automatic Update in Part and Automatic Update in product option. 6. Go to infrastructure Part infrastructure display tab page. 7. Check ON option Parameters, Constraints and Relations. 8. Click OK to options dialog box. 9. Open TEST_SAMPLE_061121.CATPart. . OBSERVATION1: The angle value is 5.001 degrees.. . 10. Expand Parameter node in specification tree. 11. Double click on Set_Param_01 . Edit parameter dialog box appears. 12. Change the value to 500. 13. Click OK to Edit parameter dialog box. . OBSERVATION2: The angle value is changed to 354.999 degrees .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 16. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 18 GA level .
APAR Information
APAR number
HD59581
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2006-11-28
Closed date
2006-12-01
Last modified date
2006-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R518 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 December 2006